Installation - Graco PR70 Operation & Maintenance Manual

Servo
Table of Contents

Advertisement

Installation

1. Locate PR70 Servo.
Locate on a level surface and lock casters. See Dimen-
sions on page 46 for space requirements.
2. Electrical Requirements.
Installing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Have a qualified
electrician connect power and ground to main power
switch terminals, see step 3 in this installation
procedure. All electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
NOTICE
Never connect to 480V, 3 phase power. Severe
equipment damage will occur.
NOTE:
PR70 Servo without heat requires 240VAC single
phase, 15 amps, 50/60 hertz.
PR70 Servo with heat requires 240VAC single phase,
40 amps, 50/60 hertz.
334116D
3. Connect Electrical Cord.
NOTE: Power cord is not supplied.
Electrical Cord Wires
240V, 1 phase: L1, L2, GND
Typical Voltage Readings 240V, 1 phase:
L1-L2: 240V
L1 or L2-GND: 115V
Use a screwdriver to connect the two power leads to L1
and L2. Connect green to ground (GND).
L1
L2
Installation
GND
7