Troubleshooting - Graco PR70 Operation & Maintenance Manual

Servo
Table of Contents

Advertisement

Troubleshooting

Troubleshooting
Before starting any troubleshooting procedures, perform
the following procedure. See PR70 and PR70v Repair -
Parts manual referenced at the beginning of this manual
for detailed procedures.
1. Relieve pressure. See Pressure Relief Procedure,
page 31.
Problem
Display Module completely dark
No or incorrect amount of material
dispensed from either side.
Piston stalled
Significant material leaking from
pump rear seal
38
2. Disconnect AC power from the machine.
3. Allow the machine to cool if the machine has a heat
Try the recommended solutions in the order given for
each problem to avoid unnecessary repairs. Verify all
circuit breakers, switches, and controls are properly set
and wiring is correct.
Cause
No power
Fuse blown
Loose connection
Bad display module
Ball valve closed (if installed)
Tank empty
Tank clogged
Air in material
Check valve malfunction
Piston worn or broken
Input air reduced or removed
Mixer blocked
Open Dispense Valve (ODV) adjust-
ment too late
Blocked check valve
Actuator failure
Pump shaft worn and/or shaft seal
worn
control option.
Verify rear AC Power switch is ON.
Replace machine fuses.
Tighten cable on Display Module.
Replace Display Module.
Open tank ball valve.
Fill tank with material.
Verify no obstruction in the tank.
Prime the machine until the air is
removed.
Remove; clean or replace check
valve.
Remove and replace piston if worn.
Reconnect input air line to machine.
Increase air pressure regulator
adjustment.
Replace static mixer.
Incorporate purge timer or decrease
purge timer delay to prevent mixer
blockage.
Readjust the ODV setting to occur
sooner.
Remove check valve; clean and
replace.
Replace actuator/servo motor.
Remove pump shaft assembly, and
reinstall rear pump rebuild kit.
Solution
334116D

Advertisement

Table of Contents
loading

This manual is also suitable for:

U81923U82204

Table of Contents