Fig. 31 Attach thermostat handle.
ST635
Encore

The Encore Controls

Install thermostat
handle
Two controls regulate the performance of the Encore: a
2/01
primary air control supplies oxygen for the fire, and a
damper directs air flow within the stove to activate and
deactivate the catalytic combustor.
Symbols cast into the stove are reminders of the correct
directions for opening and closing the controls. The
symbols assume that you are facing the front of the
stove.
Damper Handle
Ashdoor
Handle
Andirons
Fig. 33 The Encore controls are conveniently located and
easy to operate.
ST633
A Single Air Control Regulates
Encore
Heat Output and Burn Time
controls
The primary air control lever, located on the right side
2/01
of the stove, controls the amount of incoming air for
starting, maintaining, and reviving a fire.
More air entering the stove makes the fire burn hotter
and faster, while less air prolongs the burn at a lower
heat level. High and low settings appear in Figure 34.
2000956
ST635

Operation

Griddle Handle
Door Handle
Air Control
Lever
Door Handle
Holder (Be-
hind leg)
ST636
Encore Woodburning Stove
Fig. 32 Assemble the front door handle.
For the greatest air supply and maximum heat output
(but the shortest burn time), move the lever toward the
ST540
Assembly
front of the stove. For a fire that will last longer with less
handle
heat, move the lever toward the rear of the stove.
11/00
The Encore's air control system also features an
automatic thermostat to ensure an even heat output
at whatever manual setting you select. The thermostat
senses the heating and cooling of the stove surface
and adjusts the air shutter accordingly.
Low Heat
High Heat
Fig. 34 The handle may be positioned anywhere between the
two extremes for different heat levels.
A Damper Directs Air Flow
Within the Stove
ST637
The damper handle on the left side of the stove opens
and closes the damper to direct air flow within the
encore
stove.
The damper is open when the handle points to the
Air control
back of the stove, enabling smoke to pass directly into
the chimney. The damper must be open when starting
or reviving a fire, and whenever the griddle or doors are
2/01
opened.
ST540
ST637