Product Features; Gas Pressures; Gas Specifications; Ignition Controls - Vermont Castings CSVF20SNV Installation & Operating Instructions Manual

Unvented gas cast iron stove
Table of Contents

Advertisement

PRODUCT FEATURES

Handle
Optional Remote
Receiver
Piezo
Hi/Lo Knob
Off/Pilot/On Knob
Fan Switch
Figure 1 -
Cast Iron Stove (Single Door)

GAS PRESSURES

Regulator Pressure
Pilot Regulator
Max. Gas Inlet Pressure
Min. Gas Inlet Pressure

GAS SPECIFICATIONS

Model
Fuel
CSVF20SNV
Nat.
CSVF20SPV
LP
CSVF30SNV
Nat.
CSVF30SPV
LP
VFCS20DNV
Nat.
VFCS20DPV
LP
VFCS30DNV
Nat.
VFCS30DPV
LP
NOTE: An external regulator is required to reduce supply
pressure to a maximum of 10.5" w.c. on Natural Gas sys-
tems operating at higher pressure.
NOTE: An external regulator is required to reduce supply
pressure to a maximum of 13.0" w.c. for LP systems.
58D6002
ST1164
Door
ST1164
Natural
Propane (LP)
CSVF controls
3.5" w.c.
10.0" w.c.
3.5" w.c.
n/a
10.5" w.c.
13.0" w.c.
5.0" w.c.
11.0" w.c.
Max.Input Min. Input
Control
BTU/h
Millivolt
10,000
Millivolt
10,000
Millivolt
32,000
Millivolt
32,000
Millivolt
10,000
Millivolt
10,000
Millivolt
32,000
Millivolt
32,000
O N
O FF
On/Off
Switch
Break-Away
Handle
Optional
Remote
Receiver
Piezo
Hi/Lo Knob
Off/Pilot/On Knob
Figure 2 -
Cast Iron Stove (Double Door)

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of
matches.
Millivolt control has four (4) positions:
OFF
IGN
ON
LOW/HI -
BTU/h
6,000
6,000
20,000
PILOT/ODS
20,000
The gas log heater is fitted with a specially designed safety
6,000
pilot (ODS assembly) light which senses the amount of
6,000
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
20,000
level. The pilot can only be relit when adequate fresh air
20,000
is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a millivolt thermopile
generator to provide power for remote activation.
Unvented Cast Iron Gas Stoves
Optional Fan Switch
ST1165
VFCS controls
-
All gas to the burner is shut off at
the valve.
-
Valve position to light/maintain a
standing pilot.
-
Valve position to turn burners ON/
OFF with remote switch.
Variable position to control flame
height (heat output). Both front and
rear burners are in operation to pro-
vide realistic glow and yellow flame.
On/Off
Switch
O N
O FF
Store Break-
Away Handle
Here
5

Advertisement

Table of Contents
loading

Table of Contents