2SHUDWLQJ ,QVWUXFWLRQV

A. The Dauntless FlexBurn
Two controls regulate the performance of the Dauntless
®
FlexBurn
: a primary air control VXSSOLHV R[\JHQ IRU WKH ¿UH
and a damper GLUHFWV DLU ÀRZ ZLWKLQ WKH VWRYH WR DFWLYDWH DQG
deactivate the combustion system, Figure 2.1.
Symbols on the stove are reminders of the correct directions
for using the controls. The words 'Left' and 'Right' in these
directions are facing the stove.
Damper
+DQGOH
'RRU +DQGOH +ROGHU
%HKLQG OHJ
)LJXUH   7KH 'DXQWOHVV )OH[%XUQ
located and easy to operate.
$6LQJOH$LU &RQWURO 5HJXODWHV +HDW 2XWSXW DQG %XUQ 7LPH
The primary air control lever, on the right of the stove,
controls the amount of incoming air for starting, maintaining,
DQG UHYLYLQJ D ¿UH
2QFH WKH DLU FRQWURO LV PDQXDOO\ VHW D ELPHWDOOLF WKHUPRVWDW
automatically maintains the heat output at a constant level
for a more even heat over the life of the burn.
0RUH DLU HQWHULQJ WKH VWRYH PDNHV WKH ¿UH EXUQ KRWWHU DQG
faster, while less air prolongs the burn at a lower heat output
level.
)RU WKH JUHDWHVW DLU VXSSO\ DQG PD[LPXP KHDW RXWSXW EXW
WKH VKRUWHVW EXUQ WLPH  PRYH WKH OHYHU WRZDUG WKH IURQW RI
WKH VWRYH )RU D ¿UH WKDW ZLOO ODVW ORQJHU ZLWK OHVV KHDW PRYH
the lever toward the rear of the unit, Figure 2.2.
7KLV ZRRG KHDWHU KDV D PDQXIDFWXUHGVHW PLQLPXP ORZ
EXUQ UDWH WKDW PXVW QRW EH DOWHUHG ,W LV DJDLQVW IHGHUDO
regulations to alter this setting or otherwise operate this
wood heater in a manner inconsistent with operating
instructions in this manual.
8
®
Controls
'RRU +DQGOH
Ashdoor
+DQGOH
®
controls are conveniently
WARNING
Vermont Castings • Dauntless FlexBurn Owner's Manual_R17 • 2020 - ___ • 09/23
Low Heat
)LJXUH   The handle may be positioned anywhere between the
WZR H[WUHPHV IRU GL HUHQW KHDW OHYHOV
Air
A Damper Directs Air Flow Within the Stove
Control
Lever
The damper handle on the left side of the stove operates
WKH GDPSHU WR GLUHFW DLU ÀRZ ZLWKLQ WKH VWRYH
The damper is open when the handle points to the rear,
enabling smoke to pass directly into the chimney. The damper
PXVW EH RSHQ ZKHQ VWDUWLQJ RU UHYLYLQJ D ¿UH DQG ZKHQHYHU
the griddle or doors are opened.
The damper is closed when the handle points down. Smoke
travels through the secondary combustion system where
it can be further burned, before passing up the chimney,
Figure 2.3.
The damper should always be either fully open or fully
closed. There are no intermediate positions. When
FORVLQJ WKH GDPSHU EH VXUH WR SXOO ¿UPO\ HQRXJK WR VQDS
the handle into the locked position.
Damper Positions
&ORVHG +LJK ( FLHQF\ 0RGH
)LJXUH   7KH GDPSHU LV HLWKHU RSHQ RU FORVHG 7KHUH DUH QR
intermediate positions.
+LJK +HDW
2SHQ 8SGUDIW 0RGH
3-90-586000C