Clearance to Combustibles

Top of Unit to Ceiling ................................ 36" (914 mm)
Front of Unit to Combustibles
Appliance
Top Standoffs .............................................. 0" (0 mm)
Bottom ......................................................... 0" (0 mm)
Side Standoffs ............................................. 0" (0 mm)
Back Standoffs ............................................ 0" (0 mm)
Venting
Horizontal Termination through-a-side wall:
Vertical Sections:
Sides ................................................ 2¹⁄₂" (64 mm)
Horizontal Sections:
Top .................................................. 3¹⁄₂" (89 mm)
Bottom ............................................. 1¹⁄₂" (38 mm)
Sides ................................................ 2¹⁄₂" (64 mm)
Vertical Vent Application:
Sides ............................................... 1¹⁄₂" (38 mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figs. 3a and 3b, the following Mantel Charts.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
Noncombustible Finish Material
(Such as Dura Rock)
Fireplace Front
CFM146d
Mantel Chart
Mantel Shelf
Ref.
or Breast Plate Ref. of Comb. Chamber
Depth
V
10"
(254 mm)
W
9"
(229 mm)
X
8"
(203 mm)
Y
7"
(178 mm)
Z
6"
(152 mm)
Fig. 3a Combustible mantel minimum installation.
20009543
... 36" (914 mm)
(both sides)
Combustible
Framing and
Finish Wall Above
Standoffs
May use com-
bustible facing
material in this
area
Standoff
Top of Sheet Metal
Mantel from Top
A
10"
(254 mm)
B
9"
(229 mm)
C
8"
(203 mm)
D
7"
(178 mm)
E
6"
(152 mm)
Chateau™ Decorative Gas Appliance
Mantel Leg
CFM164c
Side of Fireplace
�������
������ ��� ����
�������
������� ���
Noncombustible
Finish Material
Mantel
Ref.
Leg Depth
������
F
12" (305 mm)
�� ������� �����
G
9"
(229 mm)
����
H
6"
(152 mm)
������
I
4"
(102 mm)
J
3"
(76 mm)
Fig. 3b Combustible mantel leg minimum installation.
A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12" (305 mm) or more from
the front of the fireplace. The hearth cannot exceed 1¹⁄₂"
(38 mm) in height from bottom of fireplace for ease of
door accessibility. (Fig. 4)
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory the outer walls be insulated to
conform to applicable insulation codes.
Mantel Leg from Side
Ref.
of Comb. Opening
K
12"
(305 mm)
L
9"
(229 mm)
M
6"
(152 mm)
���
N
4"
(102 mm)
O
3"
(76 mm)

Hearth

CFM170a