Locating Your Fireplace; Clearance To Combustibles; Mantels - Vermont Castings 36CDVZRRN Installation Instructions And Homeowner's Manual

Table of Contents

Advertisement

Locating Your Fireplace

E
Y
D
Y
F
Fig. 3 Locate gas fireplace.
A) Flat on wall
B) Cross corner
D) Room divider
E) Flat on wall corner
Y) Refer to "Clearance to Combustibles" Section
NOTE: (Fig. 3)
** Island (C) and Room Divider (D) installation is possible as
long as the horizontal portion of the vent system (X) does not
exceed 20' (6 m) with a minimum vertical of 4' (122 cm). See
details in Venting Section.

Clearance to Combustibles

Top of Unit to Ceiling ..................................36" (914 mm)
Front of Unit to Combustibles .....................36" (914 mm)
Appliance
Top .............................................................0" (0 mm)
Bottom ........................................................0" (0 mm)
Side ............................................................0" (0 mm)
Back ...........................................................0" (0 mm)
Venting
Concentric sections of DV Vent
Top, bottom & sides .................................1" (25 mm)
Flex Vent......................................................7/8" (22 mm)
NOTE: Hood must be permanently installed with three
(3) sheet metal screws supplied in fireplace. (Refer to
hood installation in this manual.)
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This also
applies to the distance between the mantel leg (if fitted)
and the fireplace.
For the correct mounting height and widths refer to Figs.
4a and 4b, and the following Mantel Charts.
The fitting of a bay window trim kit does not effect the
distances and reference points referred to in the diagram
and chart.
Noncombustible mantels and legs may be installed at any
height and width around the appliance.
When using paint or lacquer to finish the mantel, such paint or
lacquer must be heat resistant to prevent discoloration.
20014621
A
B
X
C
B
X
LU584-R
Locating unit
C) **Island
2/23/01 sta
F) Chase installation

Mantels

LU584-R
Mantel Shelf or
Ref. Breast Plate Depth Ref.
V
10"
W
8"
X
6"
Y
4"
Z
2"
Fig. 4a Combustible mantel minimum installation.
Black
Surround
Face
CFM164a
Side of
Combustion Chamber
CFM164a
Mantel Leg Chart
06/22/01 sta
Ref.
F
10" (254 mm)
G
8" (203 mm)
H
6" (152 mm)
I
4" (101 mm)
J
2" (51 mm)
Fig. 4b Combustible mantel leg minimum installation.
CDVZ Series Direct Vent Gas Fireplace
V
W
X
Y
Z
A
B
C
D
E
Fireplace
Hood
Mantel Chart
Mantel from Top of
CFM146
Combustion Chamber
DV Mantel Chart
7/5/01 sta
(254 mm)
A
17"
(203 mm)
B
15"
(152 mm)
C
13"
(101 mm)
D
11"
(51 mm)
E
9"
3/4" (19 mm) Scribe
Moulding for use with
Vermont Castings Group
Cabinets
Mantel
Leg
Mantel
Mantel Leg FromSide
Leg Depth
Ref.
of Comb. Opening
K
11¹⁄₂"
CFM170
L
9¹⁄₂"
DV Builder Front
M
7¹⁄₂"
View
N
5¹⁄₂"
O
3¹⁄₂"
Finish Wall
3/4" (19 mm) Scribe
Moulding for use
with Vermont Cast-
ings Group Cabinets
Standoff
Top of Combustion
Chamber
CFM146
(432 mm)
(381 mm)
(330 mm)
(279 mm)
(229 mm)
J
I
H
G
F
K
L
M
N
O
CFM170
(292 mm)
(241 mm)
(191 mm)
(140 mm)
(89 mm)
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

36cdvztrn

Table of Contents