Clearance to Combustibles

Adequate clearances as listed below must be
maintained for servicing and proper operation:
Back ............................................................... 0" (0mm)
Side .......................................................... 12" (305mm)
Floor ............................................................... 0" (0mm)
Top ........................................................... 36" (914mm)
Corner .................................... 0" to Back Edges (0mm)
Vent Pipe ...................................................... 1" (25mm)

Gas Specifications

Model
Fuel
RFSDV22RN
Natural Gas
RFSDV22RP
Propane Gas
RFSDV22TN
Natural Gas
RFSDV22TP
Propane Gas
RFSDV32RN
Natural Gas
RFSDV32RP
Propane Gas
RFSDV32TN
Natural Gas
RFSDV32TP
Propane Gas
RFSDV32RMH
Nat/Prop
RFSDV42RN
Natural Gas
RFSDV42RP
Propane Gas
RFSDV42TN
Natural Gas
RFSDV42TP
Propane Gas
Gas Inlet and Manifold Pressures
Inlet Minimum
Inlet Maximum
Manifold Pressure
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a
certified kit is available and used.
RFSDV22 / RFSDV32 / RFSDV42
Certified To
ANSI.Z21.88-2002 / CSA 2.33-2002
Vented Gas Fireplace Heaters
10001028
Max.
Input
Gas Control
B.T.U.H
B.T.U.H.
Millivolt Hi/Lo
30,000
21,000
Millivolt Hi/Lo
30,000
22,500
Thermostatic
30,000
21,000
Thermostatic
30,000
22,500
Millivolt Hi/Lo
30,000
21,000
Millivolt Hi/Lo
30,000
22,500
Thermostatic
30,000
21,000
Thermostatic
30,000
22,500
Millivolt Hi/Lo
30,000
Millivolt Hi/Lo
40,000
28,000
Millivolt Hi/Lo
37,000
27,750
Thermostatic
40,000
28,000
Thermostatic
37,000
27,750
Natural
LP (Propane)
4.5" w.c.
11.0" w.c.
14.0" w.c.
14.0" w.c.
3.5" w.c.
10.0" w.c.
RFSDV22/32/42 Freestanding Direct Vent Fireplace
Input ratings are shown in BTU per hour and
are certified without deration for elevations up
to 4,500 ft. (1,370 m) above sea level. For
elevations above 4,500 ft. (1,370 m) in USA,
installations must be in accordance with the
current ANSI Z223.1 and/ or local codes having
jurisdiction.
In Canada, please consult provincial and/ or
local authorities having jurisdiction for
installations at elevations above 4,500 ft.
(1,370 m).
Min.
Input
The use of wall paper adjacent to this
fireplace is not recommended, as the
high temperatures given off by this
fireplace may adversely effect the binders
in the adhesive used to apply the wallpa-
per.
Before beginning, remove the glass door from the
fireplace. Also check to make sure there is no hidden
damage to the fireplace. Take a minute and plan out
the gas, vent and electrical supply. See Glass Removal
N/A
Section.
When purging gas line, the front glass
must be removed.
The gas pipeline can be brought in through the rear of
the fireplace as well as the bottom. Knockouts are
provided on the bottom behind the valve to allow for
the gas pipe installation and testing of any gas connec-
tion. It is most convenient to bring the gas line in
from the rear right side of the valve, as this allows
fan installation or removal without disconnecting
the gas line.
The gas line connection can be made with properly
tinned 3/8" copper tubing, 3/8" rigid pipe or an
approved flex connector. Since some
municipalities have some additional local codes, it
is always best to consult your local authority and
the CSA- B149.1 installation code.
For U.S. Installations
Fuel Gas Code, ANSI Z223.1.
Always check for gas leaks with a mild
soap and water solution. Do not use an
open flame for leak testing.
The gas control is equipped with a captured screw type
pressure test point, therefore it is not necessary to
provide a 1/8" test point up stream of the control.

High Elevations

Preparation

Gas Line Installation

consult the current National