Setting the Sync Mode
The Sync Mode is a mode to perform measurement in synchronization with the fluctuation frequency of a light source that
fluctuates brightness at a constant cycle, such as the vertical synchronization frequency of a display unit.
* Synchronization frequency setting range: 0.50 to 240.00 Hz
* Factory setting:
Operating Procedure
1
While the measurement screen is
displayed, press the [MENU] key.
The setting screen is displayed on the LCD screen.
2
Press the [UP] or [DOWN] key to select
[Meas Cond], and then press the [RIGHT]
or [ENTER] key.
3
Press the [UP] or [DOWN] key to select
[Sync Mode], and then press the [ENTER]
key.
4
The screen for selecting a Sync mode is
displayed. Press the [UP] or [DOWN] key
to select a Sync mode.
• When selecting NTSC, sampling is performed
using a frequency of 59.94 Hz and an integration
time of 33.3 msec.
• When selecting PAL, sampling is performed using
a frequency of 50 Hz and an integration time of
40.0 msec.
• When selecting UNIV, sampling is performed
using an integration time of 100 msec.
• When selecting INT, also set a frequency.
(Generally 0.50 to 240.00 Hz, but 0.50 to 130.00
Hz for FMA)
• When selecting EXT, input the synchronization
signal to the probe or the instrument.
• When selecting MANUAL, also set an integration
time. (4.0 to 4000.0 msec)
4
-1-1 When selecting [INT], press the [ENTER]
key to display the screen for setting a
synchronization frequency.
UNIV.
68
[Meas Cond] - [Sync Mode]
M e a s C o n d
S y n c M o d e
U s e r C a l i b
M e a s S p e e d
T a r g e t
T r i g g e r M o d e
I n t e r v a l M e a s
O p t i o n
S y s t e m
I n t e r v a l A l e r t
J E I TA f r e q r e s o l u t i o n
MENU
M e a s C o n d
S y n c M o d e
U s e r C a l i b
M e a s S p e e d
T r i g g e r M o d e
T a r g e t
O p t i o n
I n t e r v a l M e a s
S y s t e m
I n t e r v a l A l e r t
J E I TA f r e q r e s o l u t i o n
MENU
M e a s C o n d
S y n c M o d e
M e a s S p e e d
U s e r C a l i b
T a r g e t
T r i g g e r M o d e
O p t i o n
I n t e r v a l M e a s
S y s t e m
I n t e r v a l A l e r t
J E I TA f r e q r e s o l u t i o n
MENU
M e a s C o n d
S y n c M o d e
M e a s S p e e d
U s e r C a l i b
T a r g e t
T r i g g e r M o d e
O p t i o n
I n t e r v a l M e a s
S y s t e m
I n t e r v a l A l e r t
J E I TA f r e q r e s o l u t i o n
Trigger mode 0-cal AUTO
NTSC
AUTO
OFF
OFF
OFF
0.07 Hz
Trigger mode 0-cal AUTO
NTSC
AUTO
OFF
OFF
OFF
0.07 Hz
Trigger mode 0-cal AUTO
◉ NTSC
○ PAL
○ UNIV
○ INT[400.00 Hz]
○ EXT
○ MANU[1000.0 ms]
Trigger mode 0-cal AUTO
◉ NTSC
○ PAL
○ UNIV
○ INT[400.00 Hz]
○ EXT
○ MANU[1000.0 ms]