General Information; General Information; Operator's Manual; Can−Bus Communications - Toro Reelmaster 3550-D Service Manual

Hide thumbs Also See for Reelmaster 3550-D:
Table of Contents

Advertisement

General Information

Operator's Manual

The Operator's Manual provides information regarding
the operation, general maintenance and maintenance
intervals for your Reelmaster machine. Refer to the Op-
erator's Manual for additional information when servic-
ing the machine.
Toro Electronic Controller (TEC)
The Reelmaster machines use a single Toro Electronic
Controller (TEC) to manage machine electrical func-
tions. The TEC controller is attached to the control pan-
el.
The controller is a microprocessor that senses the
condition of various machine switches (inputs) and di-
rects electrical power to control appropriate machine
functions (outputs) based on the state of the inputs. The
status of inputs to the controller as well as outputs from
the controller can be checked with the Diagnostic Dis-
play (see Special Tools in this chapter).
CAN−bus Communications
The TEC controller used on the Reelmaster machines
can communicate with other electrical components on
a CAN−bus communication system. The CAN−bus sys-
tem reduces the number of electrical components and
connections used on the machine and allows the num-
ber of wires in the wire harness to be reduced.
CAN identifies the Controller Area Network that is used
on the Reelmaster. Two (2) specially designed, twisted
cables form the bus. These wires provide the data path-
ways between machine components. The engineering
term for these two (2) cables are CAN−high and CAN−
low. At the ends of the twisted pair of bus cables are 120
ohm termination resistors.
Electrical System
Because of the solid state circuitry built into the Toro
Electronic Controller (TEC), there is no method to test
it directly. The TEC may be damaged if an attempt is
made to test it with an electrical test device, such as a
digital multimeter.
IMPORTANT: Before performing any welding on the
machine, disconnect the battery cables from the
battery, disconnect the wire harness connectors
from the Toro Electronic Controller and disconnect
the terminal connector from the alternator to pre-
vent damage to the machine electrical system.
Each of the components that is controlled by the CAN−
bus link only needs four (4) wires to operate and commu-
nicate to the system: CAN−high, CAN−low, B+ (power)
and ground.
IMPORTANT: The termination resistors at the ends
of the bus cables are required for proper electrical
system operation.