12V POWER
(7.5A FUSES)
12V LOGIC
POWER
(2 AMP FUSE)
VOLTAGE
OUT
IGNITION
SWITCH
INPUTS
DIGITAL
INPUTS
(OPEN/
CLOSED)
ANALOG
INPUTS
(VARIABLE)
Figure 31
Reelmaster 3550--D/3555--D/3575--D
OUTPUTS
(PWR 2)
OUTPUTS
(PWR 3)
OUTPUTS
(PWR 4)
COMM
PORT
1. TEC controller
2. Harness connector
CAN BUS
If the wire harness connector is removed from the TEC
controller for any reason, tighten the harness connector
GROUND
screw from 25 to 28 in- -lb (2.8 to 3.2 N·m).
Page 5 - - 29
Figure 32
3. Socket head screw
Electrical System