Connecting DC Power to IW-6300H-DC-x-K9
Connecting DC Power to IW-6300H-DC-x-K9
Warning
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than:5 A. Statement 1005
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement 1022
Warning
To reduce risk of electric shock, connect the unit only to DC power source that complies with the Safety
Extra-Low Voltage (SELV) requirements in IEC 60950 based safety standards or ES1 requirements in IEC
62368 based safety standards. Statement 1033
To route and connect the power cable to the IW-6300H-DC-x–K9 model, follow these steps:
Procedure
Step 1
Open the access point cover. See
Step 2
Ensure a 6 AWG ground wire is connected to the access point (see
Step 3
Route the power cable through the 1/2-NPT port.
Figure 18: Connecting Internal Ground and DC Power for IW-6300H-DC-x-K9
1
Step 4
Use a wire stripper tool to remove the insulation from each wire. Remove only enough wire to provide adequate
crimp on to ring terminals (Cisco supplied).
Installing the Access Point
26
Opening the Access Cover, on page 13
Terminal block
for instructions.
Grounding the Access Point , on page
2
Internal ground
Installing the Access Point
19).