Wiring Connectors; 6 Pin Power Connector; 11 Pin Connector; 4 Pin Connector - Ultra Start 1350 Installation Manual

Advanced remote vehicle starting system
Hide thumbs Also See for 1350:
Table of Contents

Advertisement

Installation Guide

6 Pin Power Connector

Yellow
Starter
Green
Heater
Red
12 power
Red
12 power
Blue
Ignition 1
White
Select Out

11 Pin Connector

Yellow
Re-Arm
Red/White
3rd CH
Brown
Disarm
Orange
(-) Out
White/Blue
Horn
Black/White
Park Brake
Purple
(+) Door
White
Park Lights
Green/White
Hood Pin
Green
(-) Door
Black
Ground

4 Pin Connector

White/Violet
(-) Running
Blue
Glow Plug
Blue/White
Tach
Pink
Brake
3 Pin Connector Red
Green
Door Lock
Red
12vlt Output
Blue
Door Unlock
2 Pin Connector
N/A
Ground
N/A
Temp Sensor
4 Pin Connector Blue
Antenna/ Program Button Connector.
The Antenna Must Be Connected Before the System will Operate.
Jumper Selectable Output
This output is designed to power addition ignition circuits. Most new vehicles will have either a second
ignition, accessory or starter wire that must be energized. Connect the white wire from the 6-pin
connector to the additional circuit and set the jumper for the appropriate output.
Position One Second Starter Output From The White Wire On The 6-Pin Connector.
Position Two Second Accessory Output From The White Wire On The 6-Pin Connector.
Position Three Second Ignition* Output From The White Wire On The 6-Pin Connector.
* The Default Setting For The System Is Second Ignition Output.
The jumpers control the output from the white wire at the 6-pin harness. Place the jumper in the
following positions to change the output.
Output on White wire
Second Starter
Second Accessory
Second Ignition
30amp output
30amp output
30amp input
30amp input
30amp output
30amp output
0.75sec Pulse With Lock And On Shutdown.
Trunk Release - Active When The Unlock Is Held For 3seconds.
0.75sec Pulse With Unlock And Before Start.
(-) While Running / Negative While Locked - **Starter Program Mode.
(-) Horn Honk Output - ** User Program Mode
Negative Park Brake Input - Manual Transmission Models Only.
Positive Door Trigger Input - Manual Transmission Models Only.
Positive Park light Output - 10 Amp Max.
Negative Hood Pin Input - MUST BE CONNECTED!!
Negative Door Trigger Input - Manual Transmission Models Only.
System Ground Input - MUST BE CONNECTED!!
(-) Output while running. (Output for security bypass modules...)
Diesel Glow plug input Positive or Negative. Programmable.
Tach Signal Input - MUST BE CONNECTED!!
Positive Brake Input - MUST BE CONNECTED!!
Door Lock Output - Programmable - Menu 1 Setting 3.
Output for Voltage Inverter Only!
Door Unlock Output - Programmable - Menu 1 Setting 3.
Ground output for Temperature Senor.
Input Trigger To Start.
Jumper position
1 2 3
Position 1
Position 2
Position 3

WIRING CONNECTORS

12volts during crank only.
12volts in accessory off during start.
Constant 12volt power at ignition harness.
Constant 12volt power at ignition harness.
12volts in ignition and start positions.
Selectable Output. See jumper diagram.
Jumpers
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1350m

Table of Contents