Environmental and Power Requirements

Table 1: CTP Environmental and Power Specifications
AC Input
Power required (VAC)
AC line frequency (Hz)
Nominal current
(115V amps)
Power
DC Input
Voltage (VDC)
Current
Power
Environmental
operating
temperature (°C)
Humidity
(noncondensing)
Width (inches)
Height (inches)
Depth (inches)
Weight (lb)
4
CTP System Overview
All chassis, except the CTP1002 model, have multiple cooling fans; the CTP1002
model does not use fans. Air flow is front-to-back in the CTP1004 model and
CTP1012 model, and side-to-side in the CTP2000-series.
Table 1provides a summary of the environmental and power requirements for the
CTP products.
CTP1002
CTP1004
100–240
100–132
200–240
50–60
50–60
<1.0
1.5
100 W
150 W
N/A
–40 to –72
N/A
1 A @ –48 VDC N/A
N/A
48 W maximum N/A
0–40
0–40
5–90%
5–90%
8.0
17.25
1.75
1.75
12.5
13.9
6
12
CTP1012
CTP2008
100–132
100–240
100–240
50–60
50–60
1.5
2.0
150 W
200 W
N/A
–40 to –72
3 A @ –48 VDC 3 A @ –48 VDC 4 A @ –48 VDC
144 W
maximum
0–40
0–40
5–90%
5–90%
17.25
17.25
1.75
1.75
16.75
11.25
14
12
CTP2024
CTP2056
100–240
100–240
50–60
50–60
2.0
2.5
200 W
250 W
–40 to –72
–40 to –72
144 W
192 W
maximum
maximum
0–40
0–40
5–90%
5–90%
17.25
17.25
3.5
7
11.25
11.25
20
27