Functional Description Of Carbonator Level Probe; End Of Operation (End Of Dispense-Time); Putting Out Of Service (Vacation, End Of Season); Disposal And Environment Protection - Cornelius Energize Series Manual Operation

Undercounter cooler
Hide thumbs Also See for Energize Series:
Table of Contents

Advertisement

Attention!
At the Energize FF the second carbonator pump do not start working before the carbonator bowl has
been filled to the maximum level one time. Release air from the carbonator container by pulling the
safety valve for about 2 to 4 seconds. The circulation pump has to be switch on manual by using the
switch at the controller. The circulation pump does runs in any case.
Attention!
Dry running of the circuit pump will cause damage.
6.3

Functional description of carbonator level probe

In the case the carbonator bowl is so emptied that the empty probe is out of water the electric dispensing
valves in the tower is switched off or, at the Energize FF, the second carbonator pump is switched on. That
prevents CO
in the soda water circuit and trouble during dispensing soft drinks.
2
The dispensing valves are switched back on again, or the second carbonator pump is switched off when the
carbonator bowl is filled up to the maximum level.
Attention! The switching off of the dispensing valves works only by using the factory fitted transformer for
power supply to the dispensing valve.
6.4
End of Operation (End of dispense–time)
It is imperative that the CO
6.5

Putting out of Service (Vacation, end of season)

Perform the following steps in case of longer standstill periods:
Close the CO
-cylinder, the CO
2
Pull the mains plug out of socket outlet with earthed contact.
Detach the couplings from beverage containers.
Have the system emptied and cleaned.
Only trained specialists are carry out this procedure.
6.6

Disposal and Environment Protection

Since many years the technical designers of IMI Cornelius work together with the customers to manufacture
devices which do not contain dangerous materials. They were designed in such a way that over 95% of the
used materials can be easily recycled separately.
Attention!
Do not dispose into the containers of the public collecting points for private devices.
If necessary give back your equipment free of charge at your suppliers or at all service
center of the IMI Cornelius in Langenfeld.
Cornelius Deutschland GmbH
Document no: TD1005601EN
Version A, 24.09.2019, Index 0
-cylinder and water line be turned off each time operation is ended!
2
-stopcocks on pressure regulators and the water feed line.
2
Energize R134a 60Hz
Manual operation undercounter cooler
Energize R134a 60Hz
Page 14