1.
Introduction
Our foremost aim is to produce a quality product. If you should encounter any difficulty which these operating
instructions do not help you with, call or write us. We will be glad to be of assistance. If you write, please
include the model and serial number of the device.
Our address:
2.
Safety Regulations
2.1
General Safety Regulations
This device is of leading-edge design and manufacture. If used and maintained in accordance with these
operating instructions, it will be safe to operate. Please comply with the following safety instructions to avoid
hazards and damage.
The device must be in satisfactory condition whenever operated. Any modifications which detrimentally affect
the safety of the device are therefore strictly prohibited. Please contact your service company if you wish to
obtain more information about safety.
No safety equipment (such as safety valves, overload protection devices, etc.) is to be removed, modified or
put out of commission (risk of injury or death!).
Take care that only authorized persons work on the device and that the operators are trained. Make certain that
no unauthorized persons change the settings on the device or tamper with it.
You are obligated to check the device on a daily basis for externally discernible damage and defects.
Immediately report modifications which affect safety and function to the service company nearest you.
Note that only original CORNELIUS replacement parts and accessories which have been checked and
approved are to be used. IMI Cornelius Deutschland GmbH assumes no liability whatsoever for damage
resulting from the use of non-original parts and accessories or from improper handling.
2.2
Safety Instructions Electricity
An electric shock may be fatal or result in serious injury. For this reason, any unauthorized tampering is strictly
prohibited.
Always pull out the mains plug before any cleaning work on or near the device. As delivered, it features a
moulded earthing-pin plug and it must be connected to a socket outlet with an earthing contact. This socket
outlet must be in reach ever! If no appropriate socket outlet with an earthing contact is available, the
connection must be made by authorized persons only, with the regulations applicable at the installation site
(EN standards in Europe, for example) being observed. The change of original spare parts must be
implemented by authorised Personal according to BGVA3 and VDE0701.
2.3
Safety Instructions CO
Place the carbon dioxide cylinder in an upright position next to the workstation and secure it against falling
over. Protect it against heat (e.g., against sunshine). Minimum distance from heater 0.5 m. Please only use food
approved carbon dioxide. Escaping carbon dioxide is heavier than air and may present danger of suffocation if
2
16
IMI Cornelius Deutschland GmbH
Carl-Leverkus-Strasse 15
D-40764 Langenfeld, Germany
Tel.: +49 (0) 2173 793-0
Fax: +49 (0) 2173 774 38
Internet: www.imi-cornelius.de
Linus

Advertisement

Table of Contents
loading

Summary of Contents for Cornelius Linus Series

  • Page 1 Note that only original CORNELIUS replacement parts and accessories which have been checked and approved are to be used. IMI Cornelius Deutschland GmbH assumes no liability whatsoever for damage resulting from the use of non-original parts and accessories or from improper handling.
  • Page 2: Intended Use

    Linus large quantities collect in enclosed spaces. Remember that parts of the device are at operating pressure. Do not loosen or dismantle any components at operating pressure. An operating instruction is necessary when changing the gas tank. Intended use The Linus cooler is designed for cooling beer. Food suitable CO is used for propellant.
  • Page 3: Putting Into And Out Of Service

    Linus 5.1.2 Unit with Air Compressor The unit with an compresses-air plant includes an air compressor. Connect the outlet of the compressed air plant to the CO -inlet of the tank, using tubing with an inner diameter of 4 mm. The tube connections are fitted with a G 3/4B thread.
  • Page 4 Linus End of Operation It is imperative that the CO -cylinder be turned off each time operation is ended (only units without air compressor) and pull the mains plug! Daily Inspection Check whether carbon dioxide line is open (only units without air compressor). Check the beverage line for leaks.
  • Page 5 Linus Instructions of Cleaning Comply with the national regulations for cleaning bar equipment which are valid at the particular installation site. Clean connection parts and tap fittings in advance whenever making connections or changing the type of beverage. Clean parts coming into contact with air and beverage, the mouth of the tap for example, on a daily basis. The risk of serious etching exists when handling liquid sanitisation agents.
  • Page 6: Problems And Troubleshooting

    Waste disposal and environment protection For many years the Engineers of IMI Cornelius and its customers are working hand in hand to build devices which are containing no dangerous Materials and which can be easily recycled to 95%.
  • Page 7 Linus 11. Technical Data and Pictorial Representation Linus 25 Linus 40 Linus 60 Linus 80 Linus 120 Output capacity continuously - liter per hour Refrigerant R 134a in kg 0,140 0,205 0,200 0,300 0,610 Supply voltage 230V/50Hz Power consumption in watt Compressor output in watt* 1269 Cooling...
  • Page 8: Flow Chart

    Linus 12. Flow Chart 12.1 Flow Cart with Regulator Valve for Units with Single Valve 12.2 Flow Cart with Air Compressor for Units with Single Valve...
  • Page 9: Circuit Diagram

    Linus 12.3 Flow Cart with Regulator Valve for Units with Double Valve 13. Circuit Diagram 13.1 Circuit Diagram for Units with mechanical Controller...
  • Page 10 Linus 13.2 Circuit Diagram for Linus 60 with electrical Controller C1 Starting Capacitor N1 Temperature Controller F1 Thermal Protection R2 Temperature Probe K1 Starting Relay 11; 12; 13 Mains Voltage Input M1 Compressor 6; 8 Compressor, Fan M2 Fan Motor 4;...
  • Page 11 Linus 13.3 Circuit Diagram for Linus 80 und 120 with electrical Controller C1 Starting Capacitor N1 Temperature Controller F1 Thermal Protection R2 Temperature Probe K1 Starting Relay 11; 12; 13 Mains Voltage Input M1 Compressor 6; 8 Compressor, Fan M2 Fan Motor 4;...
  • Page 12 Linus Sprengzeichnungen / Exploded drawings Mini Linus...
  • Page 13 Linus Stückliste Mini Linus / Bill of material Mini Linus 221000311 Mini Linus OTK Bier 1x BT50/7 Druckluft / Mini Linus OTK Beer 1x BT50/7 Air Pressure Sprengzeichnung / Exploded View: 221000311 Pos. Part-No. Benennung Description 149701486 Bierhahn BT 50 Valve Body BT 50 220110283 Tropfgitter...
  • Page 14 Linus Linus 40...
  • Page 15 Linus Stückliste Linus 40 / Bill of material Linus 40 Geräte-Nr.: 491571971 Pos-Nr Teilenummer Benennung Description 143387000 Tropfschale Drip Tray 143388048 Tropfblech Cup Rest 143190670 Bierhahn BT 2000 Beer Valve BT 2000 149820960 Mantelblech Sheet Metal Housing 398034400 Halteklammer Clip 142585901 Heißgasrohr Hot Gas Tube...
  • Page 16 Linus Linus 60...
  • Page 17 Linus Stückliste Linus 60 / Bill of material Linus 60 Pos. Part-Nr. Benennung Description 220093676 Bodenblech Base Plate 143277000 Gerätefuß Adjusting Foot 220093677 Mantelblech Sheet Metal Housing 141187100 Kunststoffgriffe Handle 149854401 Tropfschale Drip Tray 149854401 Tropfblech Cup Rest 143190670 Bierhahn BT2000 Beer Valve BT2000 143602000 Rosette...
  • Page 18 Linus Linus 80...
  • Page 19 Linus Stückliste Linus 80 / Bill of material Linus 80 Pos. Part-Nr. Benennung Description 220093550 Bodenblech Base Plate 143277000 Gerätefuß Adjusting Foot 220093557 Mantelblech Sheet Metal Housing 141187100 Kunststoffgriffe Handle 149687500 Tropfschale Drip Tray 149687501 Tropfblech Cup Rest 143190670 Bierhahn BT2000 Beer Valve BT2000 143602000 Rosette...
  • Page 20 Linus Linus 120...
  • Page 21 Linus Stückliste Linus 120 / Bill of material Linus 120 Pos. Part-Nr. Benennung Description 220093568 Bodenblech Base Plate 143277000 Gerätefuß Adjusting Foot 220093569 Mantelblech Sheet Metal Housing 141187100 Kunststoffgriffe Handle 149687500 Tropfschale Drip Tray 149687501 Tropfblech Cup Rest 143190670 Bierhahn BT2000 Beer Valve BT2000 143602000 Rosette...

This manual is also suitable for:

Linus 40Linus 60MinilinusLinus 80Linus 120

Table of Contents