Circuit Diagram ..........................23 Adjusting / Position of the Icebank Probe ..................25 Installation Check List ........................25 Declaration of Conformity ........................26 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 3...
Improper use Improper use of the unit and unauthorized modifications to the unit and its components may cause personal injury and equipment damage for which Cornelius Deutschland GmbH shall assume no liability. Improper use of the unit is prohibited. The following in particular is regarded as improper use:...
1.5.2 Disclaimer of liability and warranties If work is undertaken on the unit which is not described in this document, Cornelius Deutschland GmbH shall not assume any liability for any resulting hazards and damages. The same applies to described work which is partly or not fully performed in compliance with the regulations set out in this document.
Improperly executed work at the unit will cause dangers to persons and damage to the unit. Have all work at the unit carried out by Cornelius Deutschland GmbH or by a service partner. Warning! Risk of personal injury and equipment damage due to the use of non- approved spare...
Triton R134a Range Transport and packaging Choose a suitable packaging when returning the unit itself or one of its components to Cornelius Deutschland GmbH, e.g. for repairs. In particular, make sure that the unit and any components are protected from shock/impact, moisture, dirt and electrostatic discharge (ESD). This will prevent transport damage to the unit and to the components, for which the manufacturer shall assume no liability.
Due to the high flow rate, it may be necessary to install several water filters and water tubes in parallel. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0...
The Triton 2500 and Triton 700 FF require up to 560 liters water/hour. The units require also a high demand of CO2 which is more than a CORNELIUS regulator with provide and it may cause freezing up. In this case a dry and clean product tank can be used as a buffer in the line from regulator to Triton.
Long run periods are signs of leaks or too large extraction. It is then only possible to turn the pump back on by a power network reset (pulling out the mains plug briefly). Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0...
Detach the couplings from beverage containers. Have the system emptied and cleaned. Only trained specialists are carry out this procedure. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 11...
/ sanitized starting as close as possible from the mains water connection (wall outlet), to make sure that also the tubing is being treated. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0...
Page 13
Should it be necessary, to open a once sanitized system again (e.g. to install a new water filter) all opened connections must be disinfected with a sanitization spray prior to reconnecting. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0...
Page 14
In case it is seen that the nozzles are heavily dirty, clean the nozzles mechanically by using a clean brush and sanitization agent. Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0...
Page 15
The cleaning / sanitization procedure must be documented accordingly and the documentation must remain at the cooler (this may vary depending on local regulations). Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0...
Call service technician syrup in beverage is clamping (only post-mix) Delivery pressure for Adjust CO -pressure syrup too low or too high Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 16...
Cooling capacities and output capacity at 24°C ambient temperatures and water or syrup inlet temperatures of 24°C and beverage outlet temperatures of less than 5°C. When Cornelius pythons are used, a cooling loss of 13 kcal/hour per running meter must be included in calculations.
Triton 150 Procon, 350, Triton 700, Triton 2500 (example Triton 350) Connections at the Unit Triton 150 Procon Triton 350 Triton 700 Triton 2500 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 18...
Triton R134a Range Flow Chart and Circuit Diagram 10.1 Flow Chart Flow Chart Triton 150 Procon Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 19...
Page 20
Triton R134a Range Flow Chart Triton 350 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 20...
Page 21
Triton R134a Range Flow Chart Triton 700 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 21...
Page 22
Triton R134a Range Flow Chart Triton 2500 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 22...
Triton R134a Range 10.2 Circuit Diagram Circuit Diagram Triton 150 Procon, 350 and 700 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 23...
Page 24
Triton R134a Range Circuit Diagram Triton 2500 Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 24...
Triton R134a Range 13 Declaration of Conformity Manual operation undercounter cooler Cornelius Deutschland GmbH Document no: TD1014600EN Triton R134a Range Version A, 24.09.2019, Index 0 Page 26...