Pentair FLECK 5800 LXT Installer Manual page 64

Hide thumbs Also See for FLECK 5800 LXT:
Table of Contents

Advertisement

Installer manual Fleck 5800 LXT - Maintenance
Items
Valve
watertightness
Valve to piping
watertightness
* Wear parts - durability strongly affected by raw water quality and regeneration frequency.
** Electronic parts – durability strongly affected by power source quality and stability.
*** Elastomer durability is strongly affected by raw water concentration in chlorine and its
derivative.
**** Seals & Spacer cartridge is equipped with O-rings that ensure watertightness by
compression, therefore by unmounting/remounting the same cartridge may cause it not to be
watertight anymore, each time the seals & and spacer cartridge is extracted from the valve body it
must be pre-placed by a new one. Note that extraction the piston may also extract the Seals and
spacer cartridge at the same time for this reason it not advised to unmount the piston, clean and
lubricate it with silicon grease as with former residential fleck valves for the regular maintenance,
but only to replace it at least every 3 years.
64 / 96
1 year
2 year
Check
Check
Check
Check
3 year
4 year
Check
Check
Check
Check
Ref. MKT-IM-005 / F - 30.04.2020
5 year
Check
Check