Installer manual Fleck 5800 LXT - System sizing
Salt amount
[g/L
]
resin
130
140
150
170
200
230
260
290
To calculate the system mass capacity:
M
= V
× C
capacity
resin
resin ex
To calculate the system combined capacity:
C
= V
× C
capacity
resin
cor resin ex
To calculate the system volume capacity:
V
= M
/ TH
capacity
capacity
inlet
Or
V
= C
/ TH
capacity
capacity
inlet
Mandatory
If a mixing device is set on the valve before meter, use TH = TH
Having determined the previous capacity allows the operator to know the service cycle duration.
30 / 96
Corresponding resin
exchange capacity
[g/L
] as CaCO
resin
3
52.1
53.8
55.5
58.5
62.7
66.9
71
75.3
with:
M
: system mass capacity [g as CaCO
capacity
V
: volume of resin [L]
resin
C
: resin exchange capacity [g/L
resin ex
with:
C
: system combined capacity [°f.m
capacity
V
: volume of resin [L]
resin
C
: corresponding resin exchange capacity
cor resin ex
3
[°f.m
/l or °dH.m
with:
V
: system volume capacity [m
capacity
M
: system mass capacity [g as CaCO
capacity
C
: system combined capacity [°f.m
capacity
TH
: inlet water hardness [mg/L as CaCO
inlet
°dH]
3
°f.m
[per L
]
resin
5.21
5.38
5.55
5.85
6.27
6.69
7.1
7.53
resin
3
/l]
3
]
 - TH
INLET
OUTLET
Ref. MKT-IM-005 / F - 30.04.2020
3
°dH.m
[per L
]
resin
2.91
3.01
3.1
3.27
3.5
3.74
3.97
4.21
]
3
as CaCO
]
3
3
3
or °dH.m
]
3
]
3
3
or °dH.m
]
or °f or
3
 !

Hide quick links:

Advertisement

Table of Contents
loading