AA-2
TECHNICAL SPECIFICATIONS - V160-T
Input Voltages / 50 /60 Hz.
115 V (20 A Plug and branch)
115 V (30 A branch)
230 V
Duty Cycle
100%
35%
100%
Output Current Range
5-160 Amps
RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT
INPUT VOLTAGE /
FREQUENCY (HZ)
230/50/60
Height
Width
12.6 in.
7.9 in.
320 mm
200 mm
OPERATING TEMPERATURE RANGE
-20°C to +40°C

INSTALLATION

INPUT - SINGLE PHASE ONLY
RATED OUTPUT
Output Amps
Output Volts
60 (Stick)
90 (TIG)
80 (Stick)
110 (TIG)
160 (Stick)
160 (TIG)
130 (Stick)
130 (TIG)
OUTPUT
Maximum Open Circuit Voltage
48 Volts Max.
TYPE S, SO ST, STO, OR EXTRA
HARD USAGE INPUT CORD AWG
#12
PHYSICAL DIMENSIONS
Depth
16.9 in.
430 mm
TEMPERATURE RANGES
V160-S & -T
Max. Input Current at rated Output
20 A
25 A
34 A
22.4
115V (20A Plug and Branch)
13.6
23.2
115V (30A Branch)
14.4
26.4
230V (30A Branch)
16.4
25.2
230V (30A Branch)
15.2
Type of Output
MAXIMUM TIME-DELAY CIRCUIT
BREAKER OR FUSE SIZE (AMPS)
Weight
Approx. 24.2lbs.
11 kgs.
STORAGE TEMPERATURE RANGE
-50°C to +85°C
AA-2
Input Circuit
DC
30