Lincoln Electric INVERTEC V160 Operator's Manual
Lincoln Electric INVERTEC V160 Operator's Manual

Lincoln Electric INVERTEC V160 Operator's Manual

Hide thumbs Also See for INVERTEC V160:

Advertisement

Quick Links

IM2007
01/2011
Rev. 2
INVERTEC
V160
OPERATOR'S MANUAL
ENGLISH
LINCOLN ELECTRIC ITALIA S.r.l
Via Fratelli Canepa 8, 16010 Serrà Riccò (GE), Italia
www.lincolnelectric.eu

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric INVERTEC V160

  • Page 1 IM2007 01/2011 Rev. 2  INVERTEC V160 OPERATOR’S MANUAL ENGLISH LINCOLN ELECTRIC ITALIA S.r.l Via Fratelli Canepa 8, 16010 Serrà Riccò (GE), Italia www.lincolnelectric.eu...
  • Page 2: Declaration Of Conformity

    2006/95/CEE, 2004/108/CEE and has been designed in compliance with the following standards: EN 60974-1, EN 60974-10 (2001) Dario Gatti European Engineering Director Machines LINCOLN ELECTRIC ITALIA S.r.l., Via Fratelli Canepa 8, 16010 Serra Riccò (GE), Italia 12/05 English English...
  • Page 3: Table Of Contents

    12/05 THANKS! For having choosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code &...
  • Page 4: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 5: Installation And Operator Instructions

    SAFETY MARK: This equipment is suitable for supplying power for welding operations carried out in an environment with increased hazard of electric shock. CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used.
  • Page 6 connector with the key lining up with the keyway and fan will not turn OFF because the output remains rotate approximately ¼ turn clockwise. Do not over tighten. C. Gas Inlet (V160-T machines only): Connector for For DC(-) welding switch the cable connections at the the TIG shielding gas.
  • Page 7 output current during normal stick welding. This temporary increase in output current is Output LED: This indicator turns on when the used to clear intermittent connections between output of the machine is on. Both the type of the electrode and the weld puddle that occur machine and the position of the mode switch during normal stick welding.
  • Page 8 Stick Welding Mode: The meter displays the preset welding current but this is adjusted from the remote control as explained in the Output Current Control section. TIG Welding Modes: The meter displays the maximum output current which is set by the output current control knob.
  • Page 9 The machine will now recommended to contact the nearest technical service decrease the output current at a controlled rate, or center or Lincoln Electric. Maintenance or repairs downslope time, until the Crater current is reached.
  • Page 10: Electromagnetic Compatibility (Emc)

    Lincoln Electric. The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low-voltage supply system.
  • Page 11: Weee

    12/05 Part List reading instructions  Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.  Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.
  • Page 12: Accessories

    Accessories V160-T / -TP Trigger Connector (5 pins). W6100316R V160-T / -TP Remote Connector (6 pins). W6100317R V160-T / -TP Male Quick Connect Gas Fitting. W8800072R V160-T / -TP Hand Amptrol. K10095-1-15M V160-T / -TP Foot Amptrol. K870 English English...

Table of Contents