3.2.10.8 Pump Unit Removal

1.
Remove the printer mechanism unit. (Refer to Section 3.2.6.)
2.
Remove the paper eject frame. (Refer to Section 3.2.10.7.)
3.
Remove 2 screws (CBS, 3X6 and CBP, 3X8) securing the pump unit to the printer mechanism unit. Then
remove the pump unit.
Screw (CBS 3X6)
Printhead Cleaner Lever
Middle Frame Assembly
;
When mounting the printhead cleaner onto the pump unit, set the rubber part of the cleaner so it faces
the pump side.
Printhead Cleaner
Figure 3-21. Pump Unit Removal