Electric Specifications; Environmental Conditions - Epson Stylus Color 1520 Service Manual

Hide thumbs Also See for Stylus Color 1520:
Table of Contents

Advertisement

1.2.10 Electric Specifications

120 V version
Rated voltage
Input voltage range
Rated frequency renege
Input frequency range
Rated current
Power consumption
Insulation resistance
Dielectric strength
220 - 240V version
Rated voltage
Input voltage range
Rated frequency renege
Input frequency range
Rated current
Power consumption
Insulation resistance
Dielectric strength

1.2.11 Environmental Conditions

Temperature
1
Operating*
Non operating*
Humidity
1
Operating*
Non operating*
Resistance to Vibration
Operating
Non-operating*
Resistance to Shock
Operating
Non-operating*
1
Refer to the table below for guaranteed range
*
2
In shipment container
*
3
Without condensation
*
120 VAC
103.5 to 132 VAC
50 to 60 Hz
49.5 to 60.5 Hz
0.7 A (maximum)
Approximately 21 W (ISO/IEC 10561 Letter pattern)
10 M ohms min. (Between AC line and chassis, 500 VDC)
1,000 VAC rms. (1 minute) or 1,200 VAC rms. (1 second)
220 to 240 VAC
198 to 264 VAC
50 to 60 Hz
49.5 to 60.5 Hz
0.4 A (maximum)
Approximately 21 W (ISO/IEC 10561 Letter pattern)
10 M ohms min. (Between AC line and chassis, 500 VDC)
1,500 VAC rms. (1 minute) (Between AC line and chassis)
(10 to 35°C)
2
-4 to 104° F (-20 to 40° C) (for less than 1 month at 104°)
-4 to 140° F (-20 to 60° C) (for less than 120 hours at 140°)
3
*
20% to 80% RH (without condensation)
2
3
*
5% to 85% RH (without condensation)
0.15 G
2
0.50 G
1 G within 1 ms
2
2 G within 2 ms
Conforms to Energy Star program
(Between AC line and chassis)
Conforms to Energy Star program