Extron electronics TLI Pro 101 User Manual
Extron electronics TLI Pro 101 User Manual

Extron electronics TLI Pro 101 User Manual

Touchlink pro interface control systems
Hide thumbs Also See for TLI Pro 101:

Advertisement

Quick Links

User Guide
TouchLink
®
TLI Pro 101
TouchLink Pro Interface Control Systems
68-1817-01 Rev. E
04 20

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics TLI Pro 101

  • Page 1 User Guide TouchLink ® TLI Pro 101 TouchLink Pro Interface Control Systems 68-1817-01 Rev. E 04 20...
  • Page 2 Safety Instructions Safety Instructions • English Istruzioni di sicurezza • Italiano AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad WARNING This symbol, , when used on the product, is intended to avvertire l’utente della presenza di tensione non isolata pericolosa alert the user of the presence of uninsulated dangerous voltage within the all’interno del contenitore del prodotto che può...
  • Page 3 安全記事 • 繁體中文 안전 지침 • 한국어 警 告 경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는 若產品 上使 用此 符 號 , 是 為了提 醒 使 用者,產品 機 殼內 存 在 著 접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을 可能會導致觸電之風險的未絕緣危險電壓。...
  • Page 4 All trademarks mentioned in this guide are the properties of their respective owners. The following registered trademarks®, registered service marks(SM), and trademarks(TM) are the property of RGB Systems, Inc. or Extron Electronics (see the current list of trademarks on the Terms of Use page at www.extron.com):...
  • Page 5 Conventions Used in this Guide In this user guide, the following are used: Notifications WARNING: Potential risk of severe injury or death. Risque potentiel de blessure grave ou de mort. AVERTISSEMENT : CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure.
  • Page 6: Table Of Contents

    Features ...............1 Rack Mounting ...........29 Application Diagram ..........2 Underwriters Laboratories Guidelines Requirements ............2 for Rack Mounting ........29 Software ............2 Rack Mounting the TLI Pro 101 ......29 Hardware ............2 Under-desk Mounting.........29 Installation Overview ........3 Reference Material ........30 Network Port Requirements and Licensed...
  • Page 7 TLI Pro 101 • Contents...
  • Page 8: Introduction

    This guide describes the function, installation, and operation of the TLI Pro 101. Unless otherwise stated, the terms “interface” and “TouchLink Pro interface” refer to the TLI Pro 101. This section provides an overview of the TLI Pro 101: About the TLI Pro 101 •...
  • Page 9: Application Diagram

    An Extron IP Link Pro control processor must be connected to the same network domain as www.extron.com the TLI Pro 101. See for a list of suitable controllers. NOTE: The TLI Pro 101 is not compatible with Extron IP Link (non-Pro) control processors. TLI Pro 101 • Introduction...
  • Page 10: Installation Overview

    MAC address — make a note of the TLI Pro 101 MAC address. … Mount the units. Stand the TLI Pro 101 on a convenient surface, mount it in a standard rack, or use an under-table mounting kit (see Mounting on page 29).
  • Page 11 7 page 11 PoE). Set up the interface for Network Communication: Connect the PC that you will use for setup, the control processor, and the TLI Pro 101 … to the same Ethernet subnetwork. Use the Setup Menu (see page 13) or Toolbelt (see the Toolbelt Help File) to …...
  • Page 12: Panel Features, Connections, And Setup

    Panel Features, Connections, and Setup This section describes: TLI Pro 101 Rear Panel Features and Connections • TLI Pro 101 Front Panel Features • TLI Pro 101 Rear Panel Features and Connections TLI PRO 101 INPUT OUTPUT CONTROL LAN/PoE HDMI...
  • Page 13 11 PoE). NOTES: • The TLI Pro 101 ships with a 12 VDC, 1.5 A power supply and is also Power over Ethernet (PoE 802.3af, class 3) compliant. The power injector must be purchased separately. • If a 12 VDC power supply and a PoE power injector are both connected to the TLI Pro 101, the power injector takes precedence.
  • Page 14 ATTENTION: • Always use a power supply provided by or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product. • Utilisez toujours une source d’alimentation fournie ou recommandée par Extron. L’utilisation d’une source d’alimentation non autorisée annule toute conformité...
  • Page 15 2 on page 5) — Plug the cable from the input source device into this female HDMI type A connector. Secure the HDMI connector to the TLI Pro 101 with the provided LockIt HDMI lacing bracket (see “LockIt HDMI Lacing Bracket Installation”, below).
  • Page 16 The USB connection passes information to the TLI Pro 101 about where on the screen the touchpanel was pressed. To use a normal monitor instead of a touchscreen, connect a mouse to the TLI Pro 101 USB connection. Use the mouse to click screen icons.
  • Page 17 PoE power injector (not provided). ATTENTION: • The TLI Pro 101 can use a 12 VDC desktop power supply and is also Power over Ethernet (PoE 802.3af, class 3) compliant. Do not connect either power supply before reading the...
  • Page 18 ATTENTION: • The TLI Pro 101 is intended for connection to a Power over Ethernet circuit for intra- building use only and is considered to be part of a Network Environment 0 per IEC TR62101. • Le TLI Pro 101 est conçu pour une connexion à un circuit PoE pour une utilisation intérieure seulement et est considéré...
  • Page 19: Tli Pro 101 Front Panel Features

    Reset Modes on page 30). Reset button (recessed) — Allows the unit to be reset in any of three different modes (see Reset Modes). TLI Pro 101 Front Panel Features TLI PRO 101 TOUCHLINK INTERFACE MENU LINK Figure 6. TLI Pro 101 Plus Front Panel Power LED —...
  • Page 20: On-Screen Menus

    On-screen Menus On-screen menus allow initial configuration of the TLI Pro 101. Setup Menu • Calibration Screen • Setup Menu To access the setup menus, press the recessed front-panel button (see figure 6,  , on Menu page 12). The menu opens at the Status screen. There are six different screens (Status, Network, Output, Audio, Input, and Advanced) that can be selected by pressing the appropriate button in the navigation panel at the top of the screen.
  • Page 21: Network

    Network Press the button in the navigation panel at the top of the screen to open the Network Network screen. Status Network Output Audio Input Advanced Exit DHCP Host Name: XYZ-123-AB-CD-EF DNS Primary: 192.168.254.253 IP Address: 192.168.254.254 Domain Name: abcdefghijklmnop... Subnet Mask: 255.255.0.0 Mac Address:...
  • Page 22 If DHCP is disabled, set the unit IP address, subnet mask, gateway address, and DNS server address. Press the button for the address to be edited. A dialog box opens, showing the address and a numerical keypad. Figure 10. Numeric Pad for Setting IP Addresses Enter the 3-digit value for that octet (leading zeroes in an octet are ignored).
  • Page 23: Output

    Resolutions Show Figure 12. Output Screen Resolution panel shows the current resolution of the TLI Pro 101 output signal and Resolution offers three main options for setting the resolution of the TouchPanel display. Click Display Native to set the resolution of the TLI Pro 101 output to the native •...
  • Page 24 This provides better energy savings but the screen takes longer to reactivate when it is touched. Test patterns The TLI Pro 101 provides eight test patterns, which can be used to Test Pattern calibrate the third-party touchpanel display. Click the...
  • Page 25: Audio

    Audio Press in the navigation panel to open the screen. Audio Audio Status Network Output Input Advanced Audio Exit Master Click Sound HDMI Figure 15. Audio Screen Use the slider control to adjust the Master, Click, Sound, and HDMI In settings. The slider adjusts the volume setting from 0 to 100% in 1% increments.
  • Page 26: Input

    Input Status Network Output Audio Input Advanced Exit Input EDID Input Audio and Video Current Native: 1024x768 @ 60Hz Input Audio: Change Native To: Match Output HDCP 1080p @ 60Hz Authorize: Aspect Project Resolution Fill Follow Ratio: 1080p @ 60Hz Other Adjust Picture Resolutions...
  • Page 27 Input Audio and Video The two pairs of buttons on the right of the screen allow three Input Audio and Video settings to be toggled On and Off. — Enables 2CH PCM support on input EDID. Input Audio Input Input Audio is On by default. Audio: HDCP Authorize —...
  • Page 28: Advanced

    GUI Designer project that is uploaded to it. Status Network Output Audio Input Advanced Exit System GUI Project Touchpanel Name: TLI Pro 101 192.168.254.253 Room Name: Project2.gdl Resolution: 1920x1080 Controller Name: IPCP Pro 550 192.168.254.254 Creation Date: 2/25/2014 9:22:41 AM Controller IP: 192.168.254.254...
  • Page 29: Calibration Screen

    Calibration Screen Touch crosshair to calibrate 800 x 480 Figure 21. Touch Calibration Screen Press and hold down the recessed front-panel button (see figure 6,  , on Menu page 12) for at least 3 seconds. Release the button. The calibration screen opens to show cross-hairs (see figure 21, above).
  • Page 30: Configuration Software

    Plus and Professional. To obtain one, contact the Extron Sales Department. • The TLI Pro 101 is not compatible with earler Extron software (GUI Configurator or Globlal Configurator 3). Ensure you are downloading GUI Designer and Global Configurator Plus and Professional.
  • Page 31: Downloading Software From The Product Page

    Figure 23. Selecting Software to Download The software may be shown in the panels at the top of the page. Figure 23 ( ) shows Global Configurator Plus and Professional. You may need to use the left ( ) or right ( ) arrows ( ) to find the software.
  • Page 32: Downloading Software From The Alphabet Menu

    Downloading software from the alphabet menu Clicking on the initial letter of the software product (see figure , on the previous page) generates a list of software products with that initial letter. Scroll down to the product you wish to download. Figure 25 shows the panel for Toolbelt. Figure 25.
  • Page 33: Tli Pro 101 Web Page

    TLI Pro 101 Web Page To access the TLI Pro 101 default web page, enter the IP address of the unit into the web browser of a PC connected to the same subnet. A dialog opens asking for your user name and password.
  • Page 34: Updating The Firmware

    Updating the Firmware Firmware for the TLI Pro 101 can be upgraded using Toolbelt or the TLI Pro 101 web page. Before starting, consult your IT team and ensure that the interface has a unique IP address. To update firmware, first download and run the file from the Extron website. Then use Toolbelt or the TLI Pro 101 web page to upload the file to the touchpanel.
  • Page 35 Scroll down the page until you find the firmware for the TLI Pro 101. NOTE: Your product will appear in this list only if a new version of the firmware has been released since the product was first introduced. (Optional) Click...
  • Page 36: Mounting

    (such as the use of power strips). Rack Mounting the TLI Pro 101 The TLI Pro 101 can be mounted on any Extron standard rack system (not provided). See www.extron.com for a list of appropriate kits and follow the instructions included with the kit.
  • Page 37: Reference Material

    Pro Series Control Product Network Ports and Licenses Guide, which is available at www.extron.com. Reset Modes The TLI Pro 101 has three reset modes that are initiated by pressing the Reset button: Use Factory Firmware •...
  • Page 38: Reset All Ip Settings

    Result The unit reverts to factory-installed firmware. Event scripting does not start if the unit is powered on in this mode. All user files and settings such as drivers, adjustments, and IP settings are maintained. NOTE: To return the unit to the firmware version that was running prior to the reset, cycle power to the unit.
  • Page 39: Enable Or Disable The Dhcp Client

    Enable or Disable the DHCP Client This mode toggles between DHCP enabled and DHCP disabled. This can also be carried out from the Network screen of the Setup Menu (see page 13) and from the device Network tab in Toolbelt (see the Toolbelt Help File). Activation To enable or disable the DHCP client for the LAN port: Press the...
  • Page 40: Ieee 802.1X Certificates

    IEEE 802.1X Certificates IEEE 802.1X is a standard that enables port-based network access control via an authentication server. The protocol requires that all devices must be authenticated before gaining privileges to access the secure part of the network. The Extron implementation of 802.1X supports PEAP - MSCHAPV2 and EAP - TLS methods of authentication.
  • Page 41 Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.

Table of Contents