Adjusting the Minimum Burner Setting
Check whether the flame spreads to all burner ports when the burner is lit with the gas valve set to the minimum
position.
If some ports do not light, increase the minimum gas rate setting. Check whether the burner remains lit even when the
gas valve is turned quickly from the maximum to the minimum position.
If the burner does not remain lit, increase the minimum gas rate setting.
To adjust the minimum gas rate setting:
Semi-Rapid and Triple-Ring Burners:
1. Turn on the burner.
2. Turn the valve to the MINIMUM position.
3. Take off the dial.
4. Using a small flat screwdriver, turn the screw (see Fig. 12) to the correct regulation.
Inside Crown of Dual Burner:
1. Turn on the burner.
2. Turn the valve to the MINIMUM position of the inner crown only.
3. Take off the dial.
4. Using a small flat screwdriver, turn the screw (see Fig. 13) to the correct regulation.
Outside Crown of Dual Burner:
1. Turn on the burner.
2. Turn the valve to the MINIMUM position of the inner and outer crowns.
3. Take off the dial.
4. Using a small flat screwdriver, turn the screw (see Fig. 13) to the correct regulation.
For LPG, the regulation screw is normally tightened up.