Custom Door Panel Preparation - Fisher & Paykel DW24U6I1 Installation Manual

Hide thumbs Also See for DW24U6I1:
Table of Contents

Advertisement

IMPORTANT!
Ensure the custom door panel has the correct specifications
z
z
to fit the front of the dishwasher.
Ensure the back and sides of the panel are completely sealed
z
z
with a waterproof vapor barrier (ie polyurethane). The barrier
allows the panel to withstand moisture (122°F (50°C) @ 80% RH)
and prevent damage during hot and wet environment.
Measure the panel and overhang
Measure the custom panel and check the overhang length
from the base of the door.
[A] DRILL PILOT HOLES USING SUPPLIED TEMPLATE
Using the supplied Door Panel Template, mark out and drill the required pilot holes
into your custom panel. Ensure pilot holes are 1/16" (2mm) wide and 1/2" (12mm) deep.
D O O R PA NE L T EM P LA TE
59 1 5 1 8B 0 5.1 9
Use this template to accurately drill the required pilot holes in your custom door panel.
Establish the appropriate dimension below and align the template with the base of your panel.
For full installation guidance, refer to the Installation Guide supplied with your appliance.
Door overhang: 1 5/16 – 2 1/8 (34mm – 54mm)
Door overhang: 2 1/8 – 2 15/16 (54mm – 74mm)
!1

 CUSTOM DOOR PANEL PREPARATION

G A BA RI T D E P A N N E A U D E P O RT E
59 1 51 8B 0 5.1 9
Centre line
Ligne centrale
Pilot holes
Avant-trous
Utilisez ce gabarit pour percer avec précision les avant-trous destinés à la fixation
de votre panneau de porte encastré.
Déterminez la hauteur de porte appropriée ci-dessous et alignez le gabarit avec la base
de votre panneau de porte. Pour les instructions d'installation complètes, reportez-vous
au Guide d'installation fourni avec votre appareil.
Partie saillante de la porte : 1 5/16 po – 2 1/8 po (34 mm – 54 mm)
Partie saillante de la porte : 2 1/8 po – 2 15/16 po (54 mm – 74 mm)
Upper overhang detail
(when using an infill bracket)
[B] MANUALLY MARK AND DRILL PILOT HOLES
If the template is not available, mark the pilot holes manually on your custom panel based on
measurements in the below table. Ensure pilot holes are 1/16" (2mm) wide and 1/2" (12mm) deep.
If overhang is between 1 5/16" (34mm) and 2 1/8" (54mm):
PANEL A MEASUREMENTS
Base of panel to lower bracket hole
A
Base of panel to upper bracket hole
B
Base of panel to handle holes
C
Centre line to handle holes
d
If overhang is between 2 1/8" (54mm) and 2 15/16" (74mm):
PANEL B MEASUREMENTS
Base of panel to lower bracket hole
A
Base of panel to upper bracket hole
B
Base of panel to handle holes
C
Centre line to handle holes
d
Note: measurements are to center of holes.
1 5/16 – 2 15/16"
(34-74mm)
Lower overhang detail
(all custom panel installations)
D
in (mm)
4 1/16 (103)
4 7/8 (124)
18 9/16 (472)
9 1/4 (235)
in (mm)
4 13/16 (123)
a
5 11/16 (144)
19 3/8 (492)
9 1/4 (235)
D
C
B
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dw24u2i1

Table of Contents