Auto White Balance & Lv Standard Data Input - Sony DCR-IP210 Adjustment

Hide thumbs Also See for DCR-IP210:
Table of Contents

Advertisement

DCR-IP210/IP210E/IP220/IP220E
13. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: This adjustment should be carried out upon completion of "Color
Reproduction Adjustment".
Note2: After the power is turned on, this adjustment can be done only
once.
Note3: The data of page: 0, address: 10 must be "00".
Note4: Check that the data of page: 6, address: 02 is "00". If not, turn the
power of the unit OFF/ON.
Note5: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Switch setting:
1) POWER .................................................................. CAMERA
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu display) ................................... OFF
4) STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
3
6
01
0D
4
6
02
5
6
01
6
6
01
7
6
01
8
6
02
9
0
03
10
1
Note6: The adjustment data will be automatically input to page: F, address:
1A, 1B, 2E to 33.
Processing after Completing Adjustments
Order Page Address Data
1
6
01
2
0
01
3
0
03
4
Clear chart
(Color reproduction adjustment frame)
Display data of page 1 (Note5)
Adjustment remote commander
F
1A, 1B, 2E to 31
0FE0 to 1020
Display data
Procedure
01
Set the data.
Wait for 2 sec.
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note6)
00
Set the data, and press PAUSE
button.
11
Set the data, and press PAUSE
button.
0B
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note6)
1E
Set the data.
Check that the display data
(Note5) satisfies the specified
value.
Procedure
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
Perform "Auto White Balance
Adjustment".
6-30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-ip210eDcr-ip220Dcr-ip220e

Table of Contents