Byte.Bit
Encoding
2.0
Bit (1 = active)
2.1
2.2
2.3
2.4
2.5
2.6
2.7
3.0
Bit (1 = active)
3.1
3.2
3.3
3.4
3.5
3.6
3.7
Motor starter (3RK1308‑0**00‑0CP0)
Equipment Manual, 11/2019, A5E34821005002A/RS-AC/003
Process data
Meaning
DI 2.0
Ready to start for motor ON
DI 2.1
Motor CW
DI 2.2
Motor CCW
DI 2.3
Quick stop active
DI 2.4
Energy saving mode active
DI 2.5
DI module inserted
DI 2.6
Ex motor active
DI 2.7
Parameters disabled CPU/
master active
DI 3.0
Thermal model overload
DI 3.1
-
DI 3.2
I
current limit tripping
e
DI 3.3
F-DI status
DI 3.4
Residual current detected
DI 3.5
Asymmetry detected
DI 3.6
Overtemperature
DI 3.7
-
A.4 DS69 Read process image input
Relevant for
All
All
Reversing starters only
All
All
All
F starters only
All
All
-
All
F starters only
All
All
All
-
Data sets
179