6.30 Firmware update
Behavior during the firmware update
Note the following behavior during the firmware update of the motor starter:
● The LEDs flash as described in chapter "Status and error displays (Page 161)".
● The motor starter powers up again after completion of the firmware update. Diagnoses
are reset. The firmware update does not affect the thermal motor type and the cooling
time.
● The sensor supply of the DI module remains active.
Behavior after the firmware update
After the firmware update, check the firmware version of the updated module. A successfully
loaded firmware update is activated immediately.
If a fail-safe motor starter is in "Manual local" mode during the firmware update, the motor
starter switches to Commissioning mode (Page 141) after the successful firmware update
operation. You must first confirm ATEX parameters before you can perform manual local
control (see Configuring ATEX operation (Page 151)).
Online help for STEP 7
You can find more information on the procedure in the STEP 7 online help.