Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Omega Manuals
Temperature Controller
FUZZY LOGIC CN4800
Manual
Output Cycle Time - Omega FUZZY LOGIC CN4800 Manual
Hide thumbs
Omega
FUZZY LOGIC CN4800
Manual
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
page
of
102
Go
/
102
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Output cycle time
Output proportion cycle time
The relay/SSR drive output delivers the manipulated variable (0 ~
100%) as the proportion of output-off time and output-on time. The
sum of output-on time and output-off time lengths, that is the on/off
cycle time is called the output proportion cycle time.
Setting procedure
ogy Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE |
Output proportion cycle
OFF time
(Output 1 side proportion cycle time)
(Output 2 side proportion cycle time)
Parameter to be used
ON time
The output proportion cycle time is
set in sec units (1 ~ 120 sec).
Normally the following output
proportion cycle time values must
be specified.
Relay output
SSR drive output
79
20 seconds
2 seconds
Table of
Contents
Previous
Page
Next
Page
1
...
78
79
80
81
82
83
84
85
Advertisement
Table of Contents
Related Manuals for Omega FUZZY LOGIC CN4800
Temperature Controller Omega CNi8 Manual
I-series temperature & process controller manual (72 pages)
Temperature Controller Omega C9000A SERIES User Manual
Autotune temperature controller (92 pages)
Temperature Controller Omega CN63100 Series User Manual
1/16 din temperature/process controllers (92 pages)
Temperature Controller Omega CN1001-RTD User Manual
(64 pages)
Temperature Controller Omega CN710 Instruction Sheet
(2 pages)
Temperature Controller Omega CN76000 Manual
(54 pages)
Temperature Controller Omega CN1000-RTD Quick Start
Temperature controller with time proportional control (2 pages)
Temperature Controller Omega CN616TC1 User Manual
Cn616 series 1/4 din economical 6-zone pid temperature controllers (28 pages)
Temperature Controller Omega CN8200 Series User Manual
1/16 din temperature & process controllers (29 pages)
Temperature Controller Omega i Series User Manual
Temperature & process monitor, temperature & process limit alarm (57 pages)
Temperature Controller Omega CN9000A Series User Manual
(92 pages)
Temperature Controller Omega CYD211 User Manual
Single input temperature monitor (76 pages)
Temperature Controller Omega CN4000 Series User Manual
(13 pages)
Temperature Controller Omega CND3 Series User Manual
(28 pages)
Temperature Controller Omega OS212-MT User Manual
Os212 series, compact non-contact temperature sensor (35 pages)
Temperature Controller Omega OS130A Series User Manual
Non-contact infrared temperature sensor/transmitter (16 pages)
Related Content for Omega FUZZY LOGIC CN4800
CN63100 Series Cooling Output Cycle Time (Cyc2)
Omega CN63100 Series
CN9000A Series Proportional Cycle Time
Omega CN9000A Series
C9000A SERIES Proportional Cycle Time
Omega C9000A SERIES
CYD211 Input/Output Connector
Omega CYD211
i Series Figure 2.10 Communication Output Wiring Hookup A) Rs-232 Output
Omega i Series
CN8200 Series Output Types
Omega CN8200 Series
CNi8 Figure 2.11 Communication Output: A) Rs-232 Output - Wiring Hook Up
Omega CNi8
CN1001-RTD Analog And Relay Output Connections
Omega CN1001-RTD
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL