Indication And Operating Elements; Technical Data - TCS AVD Series Product Information

Front door station with integrated code lock
Table of Contents

Advertisement

Indication and operating elements

Term
LED is OFF
LED green
LED red
LED orange
bell button
code lock keypad

Technical data

supply voltage
material of the housing
colour of the housing
nameplate glass
dimensions (in mm)
camera
acceptable ambient temperature
input current in resting position (6-wire
operation)
maximum input current
8
Function
device is in basic mode, no error is detected
ON (lights up for 3 s)
∙ positive input confirmation
∙ code number accepted (can be deactivated, adjustable lighting duration)
BLINKS: device is in programming mode
ON (lights up for 3 s):
∙ wrong entry
ON (lights up for 2 min):
∙ locked (after the code was entered 3 x incorrectly)
ON (lights up permanently)
∙ entry master code
FLASHES: total error indication
trigger a door call
operation, programming of code lock functions
∙ numeric buttons from 1 to 0
∙ #-button: light switching in basic mode, input confirmation in program-
ming mode
∙ *-button: entry of command sequences and abort of incomplete com-
mand sequences in programming mode
+24 V ± 8 % (power supply and control unit)
aluminium
anodised natural
acrylic glass, printed, 5 mm thick
housing
camera field
colour camera
light sensitivity
focal length f
diagonal detection angle
video output
-20 ...+ 50 °C
I(a) = 0.6 mA
I(Pmax) = 100 mA
H 242 to 318 x W 135 x D 20
H 38 x W 82
CMOS sensor, 380 TVL
0 lux (IR on), 1 lux (IR off);
automatic daytime / nighttime operation
2.0 mm (F = 2.5)
130°
1 Vpp, symmetric, 1 Vss FBAS
I(P) = 80 mA