Install the Bath (Cont.)
B. Install the Plumbing
CAUTION: Risk of product damage. Ensure a watertight seal on the bath drain.
Connect the drain to the trap.
¨
Run water into the bath, and check the drain connections for leakage.
¨
Install the faucet valving according to the faucet manufacturer's instructions. Do not install the faucet trim
¨
until instructed. Open the hot and cold water supplies, and check the supply connections for leakage.
Ensure a seal on the bath drain and the floor drain.
¨
NOTE: An access panel will simplify future maintenance.
C. Make Electrical Connections
WARNING: Risk of electric shock. To reduce the risk of electrical shock, connect the control box to
a properly grounded, grounding-type receptacle protected by Ground-Fault Circuit-Interrupter (GFCI) or
Earth-Leakage Circuit-Breaker (ELCB). Do not remove the plug grounding pins.
NOTE: Electronic parameter label located on the controller. This label also identifies the electrical rating.
Your Kohler bath with airjets is equipped with a cord and plug. The blower motor has been wired at the
¨
factory. A licensed electrician must install a dedicated GFCI-protected or Earth-Leakage Circuit-Breaker
(ELCB), 220 V, 10 A, grounded outlet.
Plug the control box into this outlet.
¨
Clean the area of all dust and debris.
¨
D. Test Run the Bath with Airjets
Check all electrical connections, and make sure the electrical power to the bath with airjets is on.
¨
Make sure all piping connections in the air harness are secure.
¨
Verify that the blower motor is secure.
¨
Temporarily remove the plastic drop cloth or other protective sheeting from the bath.
¨
Slide the sliding slip to unlock the panel. Touch the electronic drain on/off button "
¨
The pink light flashes. Fill the bath to a level at least 10 cm above the top of the highest airjet.
Refer to "Bath Operation" to make sure that every function works well.
¨
Check the drain piping for leaks. Repair any leaks.
¨
Operate the bath and check for air flow through the airjets. Check the air piping for air leaks.
¨
Stop the bubble massage and drain the water.
¨
Return the plastic drop cloth or other protective sheeting to the bath. Check the drain connections for leakage.
¨
+
c
o
38
-
Water Temperature
1198675-X2-A
Manual Purge
Electronic Drain On/Off
Drain Pipe
Drain
Pump On/Off
6
Floor
Seal on the bath
" to close the drain.
Decreases/Increases Flow
Kohler Co.

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-45602xK-45604x