Important Safety Instructions (Cont.)
WARNING: Risk of injury or property damage. Please read all instructions thoroughly before
beginning installation, including the following Product Requirements.
NOTICE: Follow all local plumbing and electrical codes.
WARNING: Keep the area around the blower motor clean and free of debris. Ensure that the area
around the blower motor is free of sawdust, insulation, dirt, or other small loose debris. Such material
could clog the blower motor air ducts and reduce the air flow through the blower.
WARNING: Risk of damp. Silicone sealant shall be applied to connections of the bath drain pipe and the
drainage pipeline.
ATTENTION: Temperature deviation. Water temperature at different parts of the bath may not be the same,
which may cause the temperature detected and shown on the panel slightly differ from the actual water
temperature in the bath.
B.  Factory-Assembled Features
Factory installed components include blower motor with power supply cord, electronic drain, controller, check
valve, air piping, water level sensor, user keypad, and keypad cable. Other than power wiring and plumbing,
no assembly is needed.
WARNING: Unauthorized modification may cause unsafe operation or affect performance of the bath
with airjets. Do not relocate the blower motor, or make other modifications to the system in the absence
of kit instructions, as this could adversely affect the performance and safe operation of the bath with
airjets. Kohler shall not be liable under its warranty or otherwise for personal injury or damage caused by
any such unauthorized modification.
Product Requirements
A. Summary of Key Requirements
Observe all local plumbing and electrical codes.
¨
Install the unit to a level subfloor.
¨
Provide properly-dimensioned framing.
¨
B.  Plumbing Specifications
If using a rim-mounted bath faucet, flexible connections between the valves and spout may be required. Confirm
adequate mounting, connection space of specified faucet for your installation.
C.  Product Inspection
Carefully unpack and inspect the bath with airjets for damage. Leave all materials in the carton during
constructions to prevent damage.
D.  Electrical Requirements
The installation must have a Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
The GFCI or ELCB protects against Line-to ground shock hazard. Use a 220-240 V, 10 A (minimum), 50 Hz
dedicated service for the bath with airjets.
Kohler Co.
3
1198675-X2-A