All information in this manual is based upon the latest product information available at the time of publication. At Kohler, we constantly strive to improve the quality of our products. We reserve the right to make changes in product characteristics, packaging or availability at any time without notice.
Do not relocate the blower motor, or make other modifications to the system in the absence of kit instructions, as this could adversely affect the performance and safe operation of the bath with airjets. Kohler shall not be liable under its warranty or otherwise for personal injury or damage caused by any such unauthorized modification.
Please refer to rough-in for exact location of access panel. Construct brick or concrete supports. ¨ Provide a 2 mm gap between the bath rim and the concrete or brick framing. ¨ Bath 2 mm Tile Brick Typical Access Tile Brick Panel 1198675-X2-A Kohler Co.
Page 5
With help, carefully lift the bath into place. ¨ Insert the drain tailpiece into the floor drain. Make sure the bath is level and all feet are sufficiently supported. ¨ Remove the protective tape from the rim. ¨ Kohler Co. 1198675-X2-A...
Earth-Leakage Circuit-Breaker (ELCB). Do not remove the plug grounding pins. NOTE: Electronic parameter label located on the controller. This label also identifies the electrical rating. Your Kohler bath with airjets is equipped with a cord and plug. The blower motor has been wired at the ¨...
NOTE: Please read these steps carefully before you operate your bath with airjets. Troubleshoot any problems using the “Troubleshooting” section. NOTE: Please do not use the bath in case of outage. In this case, the electronic drain automatically opens and the bath can not be filled with water. Kohler Co. 1198675-X2-A...
After running for 20 minutes, BubbleMassage will automatically turn off. Press electronic drain on/off button to open the drain. When water level drops below airjet holes, auto cleaning will activate for 2 minutes. Water Temperature Decreases/Increases Flow Manual Purge Pump On/Off Electronic Drain On/Off 1198675-X2-A Kohler Co.
White-Blue 3. Light Change to Stand by Situation Water Temperature Pink 50% Blue White (Light depend on water temperature) 4. Blower Open Drain Close BBM Open Adjust the Strength of BBM Water Temperature (Blue-Orange-Red) (Pink) (Blue) (White-Blue) Kohler Co. 1198675-X2-A...
Page 10
Bath Operation (Cont.) 5. Drain Open Green 50% Blue White 6. Overflow Alarm Green (Flash) 50% Blue White 7. System Clean 50% Blue White Orange 1198675-X2-A Kohler Co.
Page 11
H. Compelling Drain Function If the overflow level sensor does not work, you can use the compelling drain function to prevent water ¨ overflow to your bathroom. Please refer to the automatic drain water level in the Roughing-in. Kohler Co. 1198675-X2-A...
Troubleshooting This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified eletrician should correct all electrical problems. For warranty service, contact your dealer or call center. Symptoms Probable Causes Recorrection Action 1. Bath with airjets does not A.
B. Lower the water level in the bath. level. C. Overflow level is not correct. C. Contact customer service personnel of Kohler to readjust the water level. 12. Water temperature cannot A. User keypad cable trips. A. Check wire connections, or replace be shown.