Troubleshooting (Cont.)
Symptoms
10. The bath cannot overflow.
11. Water level cannot be
maintained after the bath
is filled with water.
12. Water temperature cannot
be shown.
13. Abnormity shown of
water emperature.

Care and Cleaning

A. Cleaning and Care for BBM
Please confirm that the bubble massage bath is installed according to the installation instructions.
Massage system should be used at least once a month to avoid the possibility that the electrical fittings be
damaged because of excessive moisture.
Cleaning Surfaces: Do not use abrasive cleansers on any surfaces, as they will scratch and dull the surface.
Wipe out the bath after each use to prevent a build-up of soap and scum.
If the surface becomes dull, an automotive type rubbing compound *may be used on the unit, followed by
an application of paste wax.
*We recommend:
Rubbing compound mequiars mirror glaze 28 metal polish (import product) or "green oil".
B. Care and Cleaning for Adjustable Pillow
IMPORTANT INFORMATION
The bracket can not be turned forcefully or be used as grip rail. The maximum load of the bracket is 10 kg.
¨
The structure of the bracket is not absolutely tight, so it may slightly away.
¨
Please check the bracket button periodically. In case it is loose, please tighten it with hand. Otherwise, it may
¨
cause damage to the bracket.
In order to extend the service life of the product, please pay attention to the following points when caring the
products:
Sharp-pointed objects may scratch the surface of the PU elastomer.
¨
Water over 60 or soda acid solution may cause damage to the surface of the PU elastomer.
¨
Please clean the PU elastomer pillow and grip rails periodically with mild soap solution.
¨
Clean the surface with soft and wet sponge or cloth. Do not use abrasive cleaning materials like brush and
scouring pad.
Kohler Co.
Probable Causes
A. Water level sensor trips.
B. Electronic drain mechanism does
not work.
A. Water level protector functions.
B. Water level surpasses overflow
level.
C. Overflow level is not correct.
A. User keypad cable trips.
B. User keypad trips.
A. Temperature sensor of electronic
drain mechanism does not work.
Recorrection Action
A. Replace water level sensor.
B. Replace electronic drain
A. Lower the water level in the bath.
B. Lower the water level in the bath.
C. Contact customer service
A. Check wire connections, or replace
B. Replace user keypad.
A. Replace electronic drain
13
mechanism.
personnel of Kohler to readjust the
water level.
user keypad.
mechanism.