Kohler K-45600X Installation And Care Manual page 11

Bubblemassage bath
Table of Contents

Advertisement

Available languages

Available languages

Bath Operation (Cont.)
C. Air System Operation
Slide the sliding slip to unlock the panel. Touch the power button on the user keypad "
¨
Observe that the blower motor starts.
¨
Observe that air is blowing through all of the airjets.
¨
Slide in "
" direction.
¨
Verify that the air flow increases.
¨
Slide in "
" direction.
¨
Verify that the air flow decreases.
¨
Touch the power pump on/off "
¨
D. Manual Purge Operation
Drain the bath.
¨
When the bath has drained, slide the sliding slip to unlock the panel, touch the purge button once "
¨
Observe that the blower motor starts.
¨
Observe that water comes out of the airjets.
¨
Verify that touching the purge button "
¨
the cleaning will automatically stop after 2 minutes.
E.  Automatic Purge Operation
Fill the bath with at least 20cm water.
¨
Slide the sliding slip to unlock the panel. Touch pump on/off "
¨
1 minute after pump starts, slide the sliding slip to unlock the panel, touch pump on/off "
¨
pump stops.
Slide the sliding slip to unlock the panel. Touch electronic drain on/off "
¨
Observe that the blower motor starts and stops automatically after about two minutes.
¨
F.  Power Off Compelling Drain Protect Function
Slide the sliding slip to unlock the panel. Touch electronic drain on/off "
¨
Unplug the connector plugs of the controller.
¨
Observe that the electronic drain starts automatically.
¨
Plug again, the electronic drain restores its former status.
¨
NOTE: Please do not use the bath in case of outage. In this case, the electronic drain automatically opens and the
bath can not be filled with water.
G.  Test of the Overflow Function
Slide the sliding slip to unlock the panel. Touch the electronic drain on/off button "
¨
The bath is filled until the drain automatically starts and cellular sound alarm is heard. Meanwhile, the green
¨
light of "
" flashes.
Turn off the tap, water level will drop to the overflow level and the drain will stop automatically. Meanwhile,
¨
the "
" is pink. (The overflow level differs for each bath. Please refer to "Roughing-in").
NOTE: When the bath reaches overflow level, water level may rise quickly if you enter the bath or start
the bubble massage function, which may trigger the compelling drain function. Compelling drain function
will discharge lots of water, so it is not recommended to use the bath when it reaches overflow level.
H.  Compelling Drain Function
If the overflow level sensor does not work, you can use the compelling drain function to prevent water
¨
overflow to your bathroom. Please refer to the automatic drain water level in the Roughing-in.
Kohler Co.
" on the keypad to stop the blower motor.
" again stops the blower motor. If the purge button is not touched,
11
".
" , waiting for water drain.
" , the electronic drain stops.
" to close the drain.
"
" .
" again, the