5.5.3 Connector assignment X6

SU11 binary
input/output and
speed sensing via
cable SC12
5.5.4 Connector assignment X7
5-50
www.aotewell.com
Connector X6 (20-pin plug connector) connects the signals for:
• 4 binary inputs
• 4 binary outputs
• 1 speed input
The SU11 interface module can be connected via the SC12 plug-in cable
(1:1 connection from the module to the terminals):
ITDC
Designation
X6 Pin
1
Binary input 1
2
Binary input 2
3
Binary input 3
4
Binary input 4
5
Binary output 1
6
Binary output 2
7
Binary output 3
8
Binary output 4
9
P
, positive power supply, max. 30 V
ext
10
M
, 0V power supply
ext
11
Speed sensing, track 1A-
12
Speed sensing, track 1A+
13
Speed sensing, track 1B-
14
Speed sensing, track 1B+
15
Speed sensing, zero pulse 1N-
16
Speed sensing, zero pulse 1N+
17
Coarse pulse
18
GND ext.
19
GND ext.
20
n. c.
Table 5-41 Pin assignment ITDC, connector X6 and terminal assignment SU11
Connector X7 (sub-D 50-pin) connects the signals to control (gate) a SITOR
set (three-phase bridge).
Via plug-in cable:
• SC17.2 (screened round cable, 50-pin SUB-D, 2m long), or
• SC31.2 (screened round cable, 50-pin SUB-D, 10m long)
The module can be directly connected to a SITOR set.
sales@aotewell.com
Industry Automation
SU 11
Connector
X2
designation
for
configuring
1
X6A
2
3
4
5
X6G
6
7
8
9
10
11
X6C
12
13
14
15
16
17
18
19
20