26 September 1997
Mode No.
Fusing
Temperature
52
Display †
TD Sensor
Target Control
53
Voltage
Adjustment
TD Sensor
54
Gain
Adjustment
TD Sensor
Output Display
Data †
55
ADS
Reference
56
Voltage
Adjustment
ADS Output
Voltage
Display †
57
Image
Adjustment at
ID Level 1
58
Optics
Temperature
59
Display †
Drum Potential
60
Measurement
(With Paper)
Drum Potential
61
Measurement
(Without Paper)
!
Displays the fusing temperature detected by the
fusing thermistor.
Press the
key to monitor the temperature
during the normal copy cycle.
If the setting of SP30 (Toner Supply Mode
Selection) is 1 or 3, this value is used for the TD
sensor target voltage.
Normally, this value should not be changed.
When the TD Sensor initial setting is performed, this
mode is adjusted automatically.
Normally, this value should not be changed.
!
Displays the TD sensor output voltage.
Press the
key to monitor the output voltage
during the normal copy cycle.
The output voltage will display "0" when this mode is
accessed after turning on the main switch without
making any copies.
Adjusts the ADS reference voltage.
After adjusting the light intensity (SP48), place 5
sheets of A4(LT) white paper on the exposure glass
and select this mode. Adjust the ADS voltage to 2.5
V ± 0.1 V using VR101 on the main control board.
!
Displays the ADS output voltage.
Press the
key to monitor the output voltage
during the normal copy cycle.
For only this SP mode, the copies are made with the
ADS mode (other SP modes use manual ID level 4).
Adjusts the image density at ID level 1 by changing
the development bias voltage.
SP Setting
Setting
0
Normal
1
Darker
Displays the optics temperature detected by the
!
optics thermistor.
Press the
key to monitor the temperature
during the normal copy cycle.
Factory use only.
Factory use only.
Function
Dev. Bias
Note
–200
Default
–140
33
PROGRAM MODE
Settings
1 ~ 200
Default = 97
(0.02 V per step)
0 ~ 255
Default = 102
(0.04 V per step)
(0.02 V per
step) x Data
0: Normal
1: Darker

Advertisement