Product description

Intended use

The video front door station series AVD/AVE with integrated code lock is suitable for surface-mount in the outdoor
area.
Modifications and repair of the device are only permitted, as far as described in this product information
and executed by qualified electrician. Otherwise any claims under warranty and liability expire.
Always observe the current legislation and labelling requirements during assembly and operation of
video components.

Short description

Video front-door station
 Video front door stations with code lock for surface-mount with 1, 4, 6, 8, 10 or 12 bell buttons.
 Size of the nameplate: H 34 mm to 72 mm x W 74 mm (AVD), H 15 mm x W 39 mm (AVE)
 Colour: anodised natural (EN)
 colour camera CMOS sensor 380 TVL
 focal length f = 2.0 mm (F 2.5)
 light sensitivity 0 lux (IR on), 1 lux (IR off)
 diagonal detection angle 130°
 IR illumination for close-range illumination at night
 camera can be operated continuously
 metal housing made of robust aluminium profile
 bell button made of metal with maintenance-free contacts
 per bell button 2 indoor stations can be allocated
 durable and energy-saving LED name plate illumination
 shatter-proof name plate glass
 acknowledgement tone when pressing the bell button
 any bell bell button can be used to switch the light, light symbol enclosed
 conversation time ex works: 56 seconds / can be adjusted with Service Device and configo
 volume and microphone sensitivity can be adjusted manually
 pluggable memory to exchange front door stations that are identical in construction
 R-terminal to connect a functional extension: Door release
 door release time at R-terminal ex works: 3 seconds / can be adjusted with Service Device and configo
 Door call standby time ex works: 56 seconds / can be adjusted with Service Device and configo
 voice connection in door call standby time / can be adjusted with Service Device
Code lock
 switching the light by pressing the #-button without code entry, can be deactivated
 0 codes, with a maximum of 8 digits for operation
 1 master code for maintenance and configuration, leading zeros are accepted
 code stop function to activate/lock a single code (only for memory loaction 1): Connecting a time switch (or motion
detector, brightness sensor, door contact of a lock etc.) to a bipolar pluggable screw terminal is possible
 acoustic signalling when pressing the bell buttons, can be deactivated
 acoustic and optical signalling when the code is recognised
 acoustic and optical signalling when receiving a short door release protocol (if configured)
 button 5 with marking
6