Installation
Connect SINGLE Heated Hopper
Only
Modify Pump Assembly
1. Cut the white tubing (WT) approximately 11 in. (280
mm) from the end of the elbow fitting at the fluid inlet
of the pump.
2. Remove the bottle with fittings and blue hose still
attached. Save for possible later use if heating
hoses only.
3. Attach tube union fitting (5) to the pump inlet 1/2 in.
OD cut tubing end.
4. Loosen the compression nut on the pump inlet
elbow tube fitting and rotate the natural bend of the
tubing to face the direction of the single hopper.
Attach Fittings to Hopper
1. Remove the 3/4 npt plug from the bottom of the hop-
per.
2. Attach the fitting assembly (FB) to the bottom of the
hopper. Align the hose connection to face the XP
system.
3. Remove the 3/4 npt plug from the bottom side of the
hopper facing the XP system.
4. Attach the fitting assembly (FA) to the same 3/4 npt
threaded port.
22
Align and Connect Tube Fittings for One
Hopper
NOTE: When connecting tube fittings, ensure the tubing
is pushed into the fitting until it bottoms out. If there is
extra tubing, cut the tubing squarely to appropriate
length.
NOTE: The compression nut ferrules permanently crimp
to the tubing. Once the compression nuts are tightened
on the tubing, they cannot be reused on another end of
tubing.
1. Connect the 5 ft of 3/4 in. tubing (9) directly from the
hopper bottom fitting assembly to the pump inlet fit-
ting cut tube. Cut to length if necessary and tighten
both compression fittings.
2. Use the red 1/2 in. tubing assembly (from the heater
outlet) and cut the end closest to the quick discon-
nect fitting. Discard the fitting.
3. Connect 1/2 in. union fitting (UF) and 48 in. long red
tubing (RT). Tighten compression nuts.
4. Route to the single hopper side inlet fitting and cut
to length. Tighten compression nut.