Connect Xtreme-Wrap
Water-Heated Hose
NOTE: For all steps below, refer to the illustrations on
the next page.
1. Connect the female quick-disconnecting "Y" fitting
assembly (FQ) to the blue tubing quick-disconnect
from below the overflow bottles.
2. Connect the male quick-disconnect "Y" fitting
assembly (MQ) to the red tubing quick-disconnect
from the heater.
3. Connect the hose glycol circulation tubing to the "Y"
fitting assemblies. Cut the red and blue tubing
squarely behind the hose union fittings. Connect to
the "Y" fitting assembly.
NOTE: The tubes and fittings are color coded. Make
sure all colors match when connecting the fittings.
3A5314B
Connect Additional Hose
Lengths
NOTE: For all steps below, refer to the illustrations on
the next page.
Up to six 50 ft (15.2 m) sections of heated hose can be
attached for a maximum total length of 300 ft (91.4 m).
1. Remove the u-turn fittings at the end of the heated
hose assembly.
2. Connect the next length of hose, using union fittings
supplied with the hose.
NOTE: The tubes and fittings are color coded. Make
sure all colors match when connecting the fittings.
NOTE: Refer to the XP or XP-hf Proportioner manu-
als for fluid hose connections.
To prevent cross-contamination, make sure you con-
nect the "A" side fluid hose to the "A" side fluid hose
on the additional heated hose.