Rheem 325 II Series Service Instructions Manual page 52

Table of Contents

Advertisement

Component Tests 10 – 13
Test 10
Using a multimeter set on the AC voltage
scale, measure between the active (blue)
and neutral (black) terminals of the fan
plug at the controller.
Normal voltage is 240V AC.
Test 12
Unplug the fan from the controller and
using a multimeter set on the capacitance
(µF) scale, measure between the two rear
pins of the jack on the controller.
Normal capacitance is 1.5 micro Farads
(1.5µF).
TM077: 325 & 410 Series II Heat Pump Service Instructions
Rev 00: Issued April 2014
This document is stored and maintained electronically by
240
Unplug the fan from the controller and
using a multimeter set on the resistance
(ohms)
disconnected fan plug pins. The following
run and start winding results should be
obtained:
Blue & black wires (Run): 650Ω
Blue & brown wires (Start): 375Ω
1.5
Using a multimeter set on the AC voltage
scale, measure between the active (brown)
and
circulator plug at the controller.
Normal voltage is 240V AC.
Service. All printed copies are deemed uncontrolled.
Test 11
scale,
measure
Test 13
neutral
(blue)
terminals
650
between
the
240
of
the
52

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents