5.11

Configuring the Printer Interface (X4)

1070 080 037-101 (99.01) GB
Remarks
With BT220-1:
tive when you print out the diagnostic memory.
The BT220-1 in this case automatically changes the interface parameters.
After the printing process the parameters necessary for communication with
the PS 5000 (19200 bits/s; 8 data bits; even parity; 1 stop-bit) are set again.
Communication with a peripheral unit is only possible when
-
the connection cable is correctly wired (inc. any necessary Handshake
leads),
-
the interface parameter settings of both units are identical.
In the following description we assume that the BT220 is in the message dis-
play mode (see chapter 5.1, page 5-2).
1. Press the MEN key.
Procedure
The menu item "Diagnostic memory" appears in the second display line.
2. Keep pressing the B key until the text "Special function" is displayed in
the second line.
3. Press the
4. Keep on pressing the B key until the text "System functions" is displayed
in the second display line.
5. Press the
6. Keep on pressing the B key until the text "Print parameter" is displayed in
the second display line.
7. Press the
8. The current parameters are displayed in the first display line.
To change values:
To cancel the function:
9. Move the cursor with the cursor keys A and " to the setting to be
changed and enter the new value using the keys Y and B . Value range:
Baud rate: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 76800
Handshake: without =
Protocol:
10.To activate selected values:
To keep the current setting:
Proceed to step 8.
BT220 Technical Information and Operation
the settings of the interface described below are only ac-
key.
key.
key twice.
no flow control
Hardware = flow control through CTS, RTS leads
Xon/Xoff = flow control with control symbol Xon/Xoff
Xon/Xoff + DTR = inc. testing of the DSR input
7O1, 7E1, 7N2, 7O2, 7E2, 8N1, 8O1, 8E1, 8N2
1st character:
Number of data bits
2nd character:
O =odd parity
E = even parity
N = no parity
3rd character:
Number of stop-bits
Operation
Press the VAR key.
Press the MEN key twice.
Press key
Press the MEN key.
5-29
.