Electrical Specifications - Delta DVP-20PM Instruction Sheet

High-speed positioning, multi-function programmable logic controller
Hide thumbs Also See for DVP-20PM:
Table of Contents

Advertisement

...........................................................................
This instruction sheet only provides information on electrical specification, functions
and wiring. For detailed information on programming and instructions, please refer to
"DVP-PM Application Manual: Programming". For more information about the
optional peripherals, please see individual product instruction sheet or "DVP-PLC
Application Manual: Special Modules".
DVP-20PM is an OPEN TYPE device and therefore should be installed in an
enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure
should prevent non-maintenance staff from operating the device (e.g. key or specific
tools are required for operating the enclosure) in case danger and damage on the
device may occur.
DO NOT connect the AC main circuit power supply to any of the I/O terminals, or it
may damage the PLC. Check all the wirings before switching on the power. Make
sure the ground terminal
interferences. DO NOT touch any terminals when the power is on.
Product Profile & Dimension
Communication
port cover
I/O terminal No.
Function card/
memory card cover
C OM2 (R S-485)
MAN U/A UT O switch
C OM1 (R S-232)
Battery socket
Battery

Electrical Specifications

Power supply voltage
Fuse capacity
Power consumption
DC24V current output
Power protection
Withstand voltage
is correctly grounded to prevent electromagnetic
I/O terminal cover
Function card m ounting hole
164
174
100 to 240 VAC (-15 to 10%), 50/60Hz ± 5%
2A/250 VAC
60 VA
500 mA
DC24V; output short-circuited
1,500 VAC (Primary-secondary); 1,500 VAC (Primary-PE); 500 VAC
(Secondary-PE)
ENGLISH
...........................................................................
Input indicator
Output indicator
Function card port
- 1 -
I/O terminals
I/O module
connection port cover
DIN rail (35mm)
DIN rail clip
[ Figure 1 ]
POW ER /BAT.LOW /
ERR OR indicator
I/O module
connection port
Mounting screw
D irect m ounting hole
[ Figure 2 ]
Unit: mm
82.2
[ Fig ure 3 ]