Testing

T
ESTING
This section provides information about front-panel system alarms, LOS and AIS response, OCT55 test
procedure, and loopback testing.
S
A
YSTEM
LARMS
Table 21
summarizes all possible system alarms in order of priority as they appear on the front panel. When
multiple alarms occur, the front-panel display only reports the highest priority alarm. The alarm history screens
display alarms also, but provide greater detail (see
page
44). All alarms that are not inhibited will drive the front-panel Status LED to a flashing red alarm state.
Front-Panel
Alarm
(a)
Message
(b)
PWR FEED SHRT
Power Feed Short
(b)
PWR FEED GND
Power Feed Ground
(b)
PWR FEED OPEN
Power Feed Open
(b)
LOSW
Loss of Sync Word
MTA
Metallic Test Access
SPTE
Split Equipment
SPTF
Split Facilities
(b)
LLOS
Local Loss of Signal
(b)
RLOS
Remote Loss of Signal Loss of the H2TU-R DS1 input signal.
LAIS
Local Alarm Indication
Signal
RAIS
Alarm Indication Signal
at the H2TU-R
RRAI
Remote Alarm
Indication
LRAI
Remote Alarm
Indicator - Customer
Installation
TRCI
Remote Alarm
Indication - Customer
Installation
xxx-DBER
DS1 Bit Error Rate
PRMF
Performance Report
Messaging - Far End
PRMN
Performance Report
Messaging - Near End
52
"Using the Performance Screens to View Alarm Data" on
Table 21. Front-Panel System Alarms Summary
Description
A short exists between the Tip and Ring of the
HDSL2 pair.
The HDSL2 loop is grounded.
A line power open condition exists.
(c)
The HDSL2 loop has lost synchronization.
The H2TU-C is in its MTA/LOSW test state.
A test mode initiated by the HMU which splits the
AUX port's DSX-1 payload and sends it to the MUX
port.
A test mode initiated by the HMU which splits the
facility DS1 payload from the AUX port #1 and sends
it to the MUX port.
Loss of the DSX-1 input signal.
Indicates an AIS (all ones) pattern is being received
at the H2TU-C input port.
Indicates an AIS (all ones) pattern is being received
at the H2TU-R DS1 input port.
Remote Alarm Indication at the H2TU-R Indicates an
RAI alarm (yellow LED) from the CPE with errors
from the line unit or network.
Indicates an RAI alarm (yellow LED) from the CPE
with an error-free signal from the line unit or
network.
Upon reception of an RAI (yellow LED) from the
CPE, the H2TU-R sends RAI-CI toward the network
if the network signal received at the H2TU-R is clear.
If the network signal is impaired (LOS, AIS, or LOF),
then the RAI is passed on to the network unaltered.
The DS1 BER has exceeded the set 24-hour
threshold limit of approximately 10
either TUC or TUR. If TUC and TUR occur at the
same time, then TUC displays.)
Indicates H2TU-R PRM-FE BER threshold is
exceeded.
Indicates H2TU-R PRM-NE BER threshold is
exceeded.
January 9, 2002
LTPH-UM-1049-02, Issue 2
To Inhibit:
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Sets MTA option to disabled.
Sets ADS1 option to MUX or
CTHR.
Sets ADS1 option to MUX or
CTHR.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Select DIS for the DBER
-6
. (xxx denotes
system option.
Set DBER threshold to DIS.
Set DBER threshold to DIS.
H2TU-C-319 List 4E