Testing; System Alarms - ADC H4TU-C-388-L1 User Manual

Table of Contents

Advertisement

LTPH-UM-1122-02, Issue 2
T
ESTING
This section provides information about front-panel system alarms, LOS and AIS response, the OCT55 test
procedure, and loopback testing.
S
A
YSTEM
LARMS
Table 15
summarizes all possible system alarms in order of priority as they appear on the front panel. When
multiple alarms occur, the front-panel display only reports the highest priority alarm. The alarm history screens
display alarms also, but provide greater detail (see
on page
28). Alarms that are not inhibited will drive the front-panel Status LED to a flashing red alarm state.
Front-Panel
Alarm
(a)
Message
PWR FEED
Power Feed Short
(b)
SHRT
PWR FEED
Power Feed Ground
(b)
GND
PWR FEED
Power Feed Open
(b)
OPEN
SPNn-LOSW
Span(n)-Loss of Sync
(c)
Word
LLOS
Line (Unit) Loss of
Signal
RLOS
Remote (Unit) Loss of
Signal
LAIS
Line Alarm Indication
Signal
RAIS
Remote Alarm
Indication Signal
LRAI
Line RAI—Remote
Alarm Indication at the
H4TU-R (Net signal
does not have errors.)
RRAI
Remote RAI—Remote
Alarm Indication at the
H4TU-R (Net signal
has errors.)
H4TU-C-388 List 1
"Using the Performance Screens to View Performance Data"
Table 15. Front-Panel System Alarms
Description
A short exists between the Loop 1 and Loop 2
of the HDSL4 pair.
One of the HDSL4 loops is grounded.
A line power open condition exists.
The HDSL4 loop has lost synchronization.
The span closest to the network has highest
priority.
Loss of the DSX-1 input signal.
Loss of the H4TU-R DS1 input signal.
Indicates an AIS (unframed all ones) pattern
is being received at the H4TU-C DS1 input
port.
Indicates an AIS (unframed all ones) pattern
is being received at the H4TU-R DS1 input
port.
Indicates an RAI alarm (yellow) from the CPE
with an error-free signal from the line unit or
network. RAI signal is transmitted towards
the network.
Indicates an RAI alarm (yellow) from the CPE
with errors from the line unit or network.
September 12, 2003
To Inhibit:
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Disable the RDA (Remote Disconnect
Alarm) option. The front-panel Status LED
still flashes red and the ALRM RLOS
message displays to alert you of the LOS
state. LOS is sent towards the network
from the H2TU-C. This option prevents the
common occurrences of a CPE LOS
condition from generating recurring
alarms and AIS payloads.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.
Cannot be inhibited.

Testing

Continued
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

H4tu-c-388Hdsl4

Table of Contents