Whirlpool duet GGW9200L Series Job Aid page 14

Gas and electric dryers
Table of Contents

Advertisement

4-WIRE DIRECT CONNECTION
1.
Strip 5" (12.7cm) of outer covering from
the end of the cable.
2.
Cut 1-1/2" (3.8 cm) from the 3 insulated
wires. Do not cut the bare ground wire.
3.
Strip 1" (2.5 cm) of insulation from the
ends of the three wires.
4.
Twist the loose wire strands together on
each wire and form a hook in the bare wire
ends.
5.
Remove the terminal block cover hold-
down screw and open the cover at the
back of the dryer.
6.
Remove the center terminal block screw.
7.
Remove the appliance ground wire (green
with a yellow tracer) from the external
ground connector screw, and reconnect it
to the center, silver terminal block screw.
8.
Connect the ground wire (green or bare) of
the power supply cable to the external
ground conductor screw.
A
B
C
A. External ground connector
B. Green or bare copper wire of power supply
cord
C. 3/4" (1.9 cm) UL-listed strain relief
D. Center, silver terminal block screw
E. Neutral grounding wire (green/yellow)
F. Neutral wire (white)
9.
Connect the end of the neutral (white) wire
of the power supply cable to the center
screw of the terminal block.
10. Connect the ends of the remaining power
supply wires to the left and right terminal
block screws.
11. Check the wire connections and make
sure that they are all tight.
12. Tighten the strain relief clamp screws.
13. Insert the tab of the terminal block cover
into the slot of the dryer rear panel and
secure the cover with its mounting screw.
2-4
E
F
L
R
D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents