Chapter 2 - Installation; Wiring Requirements - Parker LINKnet AC30 Series Product Manual

Hide thumbs Also See for LINKnet AC30 Series:
Table of Contents

Advertisement

Chapter 2 - Installation

Wait 5 minutes after disconnecting power before working on any part of the system or removing the

Wiring Requirements:

Use only Cat 6 Shielded Ethernet, patch or crossover cable.
Ethernet Connection – (RJ45)
The Ethernet port is primarily intended for peer to peer communications with other modules in the system. Other
functions include direct support between the LINKnet module and a PC, ModBus TCP/UDP access to remote I/O,
HMI's and PLCs. A computer connected to the Ethernet connector on the LINKnet module or via an Ethernet
switch, can be used to install LINKnet configurations or monitor (Go On line) with any element within the
LINKnet network. SSD Drives graphic configuration software package Drive System Explorer 890 (DSE890)
version 3.07 and all subsequent versions support LINKnet. If you have an older version, updates may be obtained
simply by doing a HELP / CHECK FOR UPDATES within DSE or by contacting Parker SSD Drives Product
Support
AC30 Series LINKnet Product Manual HA474739U001
Before installing, ensure that the drive power is switched off and cannot be switched on
Cable Connections
PIN
1
2
3
4
5
6
7
8
Cable Specifications – patch or crossover
Cable Type
CAT6
Shielded
LINKnet
operates at the nominal rate of 100 Mbit/s.
WARNING
accidentally by other personnel.
covers from the drive.
Signal
TD+
TD-
RD+
Termination
Termination
RD-
Termination
Termination
Maximum Node-to-Node
Distance (m)
100
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linknet ac30pLinknet ac30dLinknet ac30v

Table of Contents