Further Reading; Product Features; Ethernet Protocols Supported; Software Requirements - Parker LINKnet AC30 Series Product Manual

Hide thumbs Also See for LINKnet AC30 Series:
Table of Contents

Advertisement

Further Reading

AC30 Series Drive Product Manual HA501718U002.

Product Features

• Supports Phase Locking on the AC30P/D Series drive. (LINKnet firmware version LN 1.7 or greater).
• Supports 690Like Phase Locking on the AC30D Series drive. (LINKnet firmware version LN 1.7 or greater).
• Can be used as a LINKnet communications option between AC30 drives and other LINKnet modules like the
690+, 590+ or 890 drives.
• Supports Modbus UDP/IP Master communications.
• Supports Ethernet IP communications or Modbus/TCP communications option

Ethernet Protocols Supported:

LINKnet supports the following Ethernet protocols:
1. Modbus UDP/IP Master - Supports Remote IO, Input / Output support.
2. Modbus TCP/IP Slave or Ethernet IP Server (slave). Supports implicit (Class 1) for data access.
LINKnet acts as a slave device only.
Only 1 Slave protocol can be supported per LINKnet card.
Supports TS8000 HMI Touchscreen and PLCs.
Ethernet IP Server (slave) is supported in LINKnet firmware version 1.6 or greater and DSE v 3.07 or
greater.
Supports up to 500 bytes of input data and 500 bytes of output data, using any combination of
16 bit (2 bytes) registers and 32 bit (4 bytes) registers.
Supports up to 250, 16-bit input registers & 250, 16-bit output registers
Supports up to 125, 32-bit input registers & 125, 32-bit output registers
Note: Up to 3 active Modbus TCP/IP connections are supported per LINKnet module, multiple Masters may
work but it will require more overhead. (Supported in firmware version 1.6 or greater only)

Software Requirements:

The software DSE (Drive System Explorer) & DSELite version 3.10 or greater supports the AC30 Series
LINKnet drive firmware version LN 1.7 or greater. It is always recommended to obtain the latest version of
DSE by doing a HELP / CHECK FOR UPDATES.

Hardware Supported:

The AC30 Series drives supported are:AC30V, AC30P & the AC30D including the
Feedback and IO options.

Restrictions

"Fieldbus option Communication modules" like Device Net, ControlNet etc., are not
supported, at this time. Feedback and I/O options are supported.
Registration is not supported, at this time.
AC30 Series LINKnet Product Manual HA474739U001
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Linknet ac30pLinknet ac30dLinknet ac30v

Table of Contents