X1
X2 / X3
X30
X31
X40/X41
X51 / X52 / X55
X58 / X57 / X56 / X53 /
X54
X60 / X62
X61
X111 / X112 / X113 /
X114
H500 / H501 / H502 /
H505
S1
S2
Figure 4-9
MCP Interface PN interfaces
Procedure:
1. Switch-off the control: Completely switch off the system. Check that the system is in a no-
voltage condition and is locked-out so that it cannot be switched on again without the
appropriate authorization.
2. Access the operator panel or control cabinet in which the machine control panel is located.
3. If it has not already been done, label all connectors that are inserted in the module now.
Only then, can it be ensured that the cables are not interchanged.
4. Release the screw connection for power supply X1 and remove this.
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
24 VDC power supply
PROFINET interfaces
Interface for rotary switch feed override
Interface for rotary switch spindle override
Digital inputs (24 V)
Digital inputs (TTL)
Digital outputs (24 V)
Handwheel
Reserved
Key and LED interfaces
LEDs for status display
DIP switch for the MCP IP address
DIP switch to transfer the handwheel pulse signals
Service cases - hardware
4.5 Machine control panels